A New Frontier: No Working Port for Robotic Mitral Valve Repair

Innovations (Phila). 2023 Mar-Apr;18(2):200-203. doi: 10.1177/15569845231165311. Epub 2023 Apr 10.

Abstract

A 61-year-old male presented via referral for mitral regurgitation and was deemed an appropriate robotic surgery candidate for complex mitral valve repair with the maze procedure and patent foramen ovale and left atrial appendage closures, using all percutaneous cannulation. We report upon the first case in the literature that describes the use of only 4 robotic ports, with no working port used.

Keywords: cardiac surgery; innovation; minimally invasive surgery; mitral valve; robotic surgery.

Publication types

  • Case Reports

MeSH terms

  • Cardiac Surgical Procedures* / methods
  • Humans
  • Male
  • Middle Aged
  • Minimally Invasive Surgical Procedures
  • Mitral Valve / surgery
  • Mitral Valve Insufficiency* / surgery
  • Robotic Surgical Procedures* / methods
  • Robotics*