Peri-implant Proximal Humerus Fracture Stabilized with Stacked Plating: A Case Report

J Orthop Case Rep. 2023 Mar;13(3):8-12. doi: 10.13107/jocr.2023.v13.i03.3564.

Abstract

Introduction: A peri-implant proximal humerus fracture is a rare complication after open reduction and internal fixation (ORIF) and poses a surgical dilemma.

Case report: A 56-year-old male sustained a peri-implant proximal humerus fracture after undergoing ORIF. We present a stacked plating method for fixation of this injury. This construct allows for decreased operative time, less soft-tissue dissection, and the ability to leave previous intact hardware in place.

Conclusion: We describe the rare case of a peri-implant proximal humerus treated with stacked plating.

Keywords: ORIF proximal humerus; Peri-implant proximal humerus fracture; proximal humerus fixation; stacked plating.

Publication types

  • Case Reports