Background: The Pipeline Flex embolization device with Shield technology (PED Shield) is the first flow diverter for brain aneurysm treatment approved in the United States using surface-modified technology. The effect of PED Shield on decreasing perioperative diffusion-weighted imaging positive (DWI+) hits, as a marker for in-human decrease thrombogenicity, is unclear.
Objective: To determine if the number of periprocedural DWI+ lesions differs between patients with an aneurysm treated with PED Flex and PED Shield.
Methods: This retrospective study compares the outcomes of consecutive patients with an aneurysm treated with PED Flex and PED Shield. The primary outcome of interest was the occurrence of DWI+ lesions. We also assessed potential predictors of DWI+ lesions and compared the outcomes between on-label and off-label treatment indications.
Results: 89 patients were included, 48 (54%) treated with PED Flex and 41 (46%) with PED Shield. After matching, the incidence of DWI+ lesions was 61% and 62% for the PED Flex and PED Shield groups, respectively. Results were consistent across each model with no significant differences in DWI+ lesions between treatment groups, and effect sizes ranging from OR=1.08 (95% CI 0.41 to 2.89) after propensity score matching to OR=1.84 (95% CI 0.65 to 5.47) after multivariable regression. Multivariable models demonstrated reduced DWI+ lesions with balloon-assisted therapies and posterior circulation treatment, while a significant linear relationship was encountered with fluoroscopy time.
Conclusion: There was no significant difference in the incidence of perioperative DWI+ lesions between patients with an aneurysm treated with PED Flex and PED Shield. Larger cohorts are likely needed to demonstrate differences between the devices.
Keywords: Aneurysm; Angiography; Device; Flow Diverter; Stroke.