Background: Conventional supine emergence and prone extubation from general endotracheal anesthesia (GEA) are associated with extubation-related adverse events (ERAEs). Given the minimally invasive nature of endoscopic retrograde cholangiopancreatography (ERCP) as well as the improved ventilation/perfusion matching and easier airway opening in the prone position, we aimed to assess the safety of prone emergence and extubation in patients undergoing ERCP under GEA.
Methods: Totally, 242 eligible patients were recruited and randomized into the supine extubation group (n = 121; supine group) and the prone extubation group (n = 121; prone group). The primary endpoint was the incidence of ERAEs during emergence, including hemodynamic fluctuations, coughing, stridor, and hypoxemia requiring airway maneuvers. The secondary endpoints included the incidence of monitoring disconnections, extubation time, recovery time, room exit time, and post-procedure sore throat.
Results: The incidence of ERAEs was significantly lower in the prone group compared with the supine group (8.3% vs 34.7%, OR = 0.17, 95% CI 0.18-0.56; P < 0.001). Moreover, the prone group demonstrated no monitoring disconnections, shorter extubation time and room exit time, faster recovery, and, lower frequency and milder sore throat after the procedure.
Conclusions: For patients undergoing ERCP under GEA, compared with supine, prone emergence, and extubation had remarkably lower rates of EAREs and better recovery, and can maintain continuous monitoring and improve efficiency.
Keywords: ERCP; Extubation-related adverse events; Prone position.
© 2023. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.