Two-Year Outcomes for Tricuspid Repair With a Transcatheter Edge-to-Edge Valve Repair From the Transatlantic TRILUMINATE Trial

Circ Cardiovasc Interv. 2023 Aug;16(8):e012888. doi: 10.1161/CIRCINTERVENTIONS.122.012888. Epub 2023 Aug 15.

Abstract

Background: Tricuspid regurgitation (TR) is a common and progressive valve disease with significant mortality and hospitalization burden. Tricuspid transcatheter edge-to-edge repair provides a treatment option for high-risk patients with primary and secondary TR.

Methods: The TRILUMINATE trial ([Trial to Evaluate Treatment With Abbott Transcatheter Clip Repair System in Patients With Moderate or Greater Tricuspid Regurgitation]; n=85) is an international, prospective, single-arm, multicenter study to investigate the safety and performance of tricuspid transcatheter edge-to-edge repair with the TriClip implant in patients with symptomatic moderate or greater TR. Echocardiographic assessment was performed at a core laboratory. Outcomes included safety and clinical effectiveness and echocardiographic assessment of TR.

Results: At 2 years, TR was reduced to moderate or less in 60% of subjects, and reduction of at least 1 grade was achieved in 85.4% of subjects. TR reduction was sustained in 75% of the patients. While most metrics suggest the majority of favorable remodeling occurred within the first 30 days post-procedure, both right ventricular end diastolic diameter and tricuspid annular plane systolic excursion show signals of continued favorable remodeling through 2 years. Substantial improvements in 6-minute walking distance, New York Heart Association functional class, and Kansas City Cardiomyopathy Questionnaire score were sustained from 30 days to 2 years. Even with low rates of cardiovascular mortality (15.3%) and all-cause mortality (18.7%) noted at 2 years, all-cause hospitalization rate decreased from 1.30 events per patient-year 1 year before device implantation to 0.66 events per patient-year 2 years after the TriClip procedure, representing a reduction of 49% (P<0.0001).

Conclusions: Tricuspid transcatheter edge-to-edge repair using the TriClip implant was found to be safe and effective, with sustained benefits at 2 years in subjects with symptomatic moderate or greater TR. Repair efficacy was durable at 2 years in 75% of the patients.

Registration: URL: https://www.

Clinicaltrials: gov; Unique identifier: NCT03227757.

Keywords: heart failure; heart valves; hospitalization; outcomes; tricuspid valve insufficiency.

Publication types

  • Multicenter Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Cardiac Catheterization
  • Heart Valve Prosthesis Implantation*
  • Humans
  • Prospective Studies
  • Severity of Illness Index
  • Treatment Outcome
  • Tricuspid Valve Insufficiency* / diagnostic imaging
  • Tricuspid Valve Insufficiency* / surgery

Associated data

  • ClinicalTrials.gov/NCT03227757