Discordance Between Creatinine-Based and Cystatin C-Based Estimated GFR: Interpretation According to Performance Compared to Measured GFR

Kidney Med. 2023 Aug 9;5(10):100710. doi: 10.1016/j.xkme.2023.100710. eCollection 2023 Oct.

Abstract

Rationale & objective: Use of cystatin C in addition to creatinine to estimate glomerular filtration rate (estimated glomerular filtration rate based on cystatin C [eGFRcys] and estimated glomerular filtration rate based on creatinine [eGFRcr], respectively) is increasing. When eGFRcr and eGFRcys are discordant, it is not known which is more accurate, leading to uncertainty in clinical decision making.

Study design: Cross-sectional analysis.

Setting & participants: Four thousand fifty participants with measured glomerular filtration rate (mGFR) from 12 studies in North America and Europe.

Exposures: Serum creatinine and serum cystatin C.

Outcomes: Performance of creatinine-based and cystatin C-based glomerular filtration rate estimating equations compared to mGFR.

Analytical approach: We evaluated the accuracy of eGFRcr, eGFRcys, and the combination (eGFRcr-cys) compared to mGFR according to the magnitude of the difference between eGFRcr and eGFRcys (eGFRdiff). We used CKD-EPI (Chronic Kidney Disease Epidemiology Collaboration) equations to estimate glomerular filtration rate. eGFRdiff was defined as eGFRcys minus eGFRcr and categorized as less than -15, -15 to <15, and ≥15 mL/min/1.73 m2 (negative, concordant, and positive groups, respectively). We compared bias (median of mGFR minus eGFR) and the percentage of eGFR within 30% of mGFR.

Results: Thirty percent of participants had discordant eGFRdiff (21.0% and 9.6% negative and positive eGFRdiffs, respectively). In the concordant eGFRdiff group, all equations displayed similar accuracy. In the negative eGFRdiff groups, eGFRcr had a large overestimation of mGFR (-13.4 [-14.5 to -12.2] mL/min/1.73 m2) and eGFRcys had a large underestimation (9.9 [9.1-11.2] mL/min/1.73m2), with opposite results in the positive eGFRdiff group. In both negative and positive eGFRdiff groups, eGFRcr-cys was more accurate than either eGFRcr or eGFRcys. These results were largely consistent across age, sex, race, and body mass index.

Limitations: Few participants with major comorbid conditions.

Conclusions: Discordant eGFRcr and eGFRcys are common. eGFR using the combination of creatinine and cystatin C provides the most accurate estimates among persons with discordant eGFRcr or eGFRcys.

Keywords: Glomerular filtration rate; creatinine; cystatin; estimated GFR.