Persistent pulmonary hypertension of the newborn (PPHN) can be monitored theoretically by the difference of the partial pressure of arterial (PaCO2) to end-tidal CO2 (EtCO2). We aimed to test the hypothesis that the PaCO2-EtCO2 gradient in infants with PPHN would be higher compared to infants without PPHN. Prospective, observational study of term-born ventilated infants with echocardiographically-confirmed PPHN with right-to-left shunting and term-born control infants without respiratory disease. The PaCO2-EtCO2 gradient was calculated as the difference between the PaCO2 measured from indwelling arterial sample lines and EtCO2 measured by continuous Microstream sidestream capnography. Twenty infants (9 with PPHN and 11 controls) were studied with a median (IQR) gestational age of 39.5 (38.7-40.4) weeks, a birthweight of 3.56 (3.15-3.93) kg and a birthweight z-score of 0.03 (- 0.91 to 1.08). The PaCO2-EtCO2 gradient was larger in the infants with PPHN compared to those without PPHN after adjusting for differences in the mean airway pressure and fraction of inspired oxygen (adjusted p = 0.037). In the infants with PPHN the median PaCO2-EtCO2 gradient decreased from 10.7 mmHg during the acute illness to 3.3 mmHg pre-extubation. The median difference in the gradient was significantly higher in infants with PPHN (6.2 mmHg) compared to infants without PPHN (-3.2 mmHg, p = 0.022). The PaCO2-EtCO2 gradient was higher in infants with PPHN compared to term born infants without PPHN and decreased over the first week of life in infants with PPHN. The gradient might be utilised to monitor the evolution and resolution of PPHN.
Keywords: Capnography; Carbon dioxide; Mechanical ventilation; Right-to-left shunt.
© 2023. The Author(s).