Aortic stenosis assessment from the 3-chamber cine: Ratio of balanced steady-state-free-precession (bSSFP) blood signal between the aorta and left ventricle predicts severity

J Cardiovasc Magn Reson. 2024 Summer;26(1):100005. doi: 10.1016/j.jocmr.2023.100005. Epub 2024 Jan 9.

Abstract

Background: Cardiovascular magnetic resonance (CMR) imaging is an important tool for evaluating the severity of aortic stenosis (AS), co-existing aortic disease, and concurrent myocardial abnormalities. Acquiring this additional information requires protocol adaptations and additional scanner time, but is not necessary for the majority of patients who do not have AS. We observed that the relative signal intensity of blood in the ascending aorta on a balanced steady state free precession (bSSFP) 3-chamber cine was often reduced in those with significant aortic stenosis. We investigated whether this effect could be quantified and used to predict AS severity in comparison to existing gold-standard measurements.

Methods: Multi-centre, multi-vendor retrospective analysis of patients with AS undergoing CMR and transthoracic echocardiography (TTE). Blood signal intensity was measured in a ∼1 cm2 region of interest (ROI) in the aorta and left ventricle (LV) in the 3-chamber bSSFP cine. Because signal intensity varied across patients and scanner vendors, a ratio of the mean signal intensity in the aorta ROI to the LV ROI (Ao:LV) was used. This ratio was compared using Pearson correlations against TTE parameters of AS severity: aortic valve peak velocity, mean pressure gradient and the dimensionless index. The study also assessed whether field strength (1.5 T vs. 3 T) and patient characteristics (presence of bicuspid aortic valves (BAV), dilated aortic root and low flow states) altered this signal relationship.

Results: 314 patients (median age 69 [IQR 57-77], 64% male) who had undergone both CMR and TTE were studied; 84 had severe AS, 78 had moderate AS, 66 had mild AS and 86 without AS were studied as a comparator group. The median time between CMR and TTE was 12 weeks (IQR 4-26). The Ao:LV ratio at 1.5 T strongly correlated with peak velocity (r = -0.796, p = 0.001), peak gradient (r = -0.772, p = 0.001) and dimensionless index (r = 0.743, p = 0.001). An Ao:LV ratio of < 0.86 was 84% sensitive and 82% specific for detecting AS of any severity and a ratio of 0.58 was 83% sensitive and 92% specific for severe AS. The ability of Ao:LV ratio to predict AS severity remained for patients with bicuspid aortic valves, dilated aortic root or low indexed stroke volume. The relationship between Ao:LV ratio and AS severity was weaker at 3 T.

Conclusions: The Ao:LV ratio, derived from bSSFP 3-chamber cine images, shows a good correlation with existing measures of AS severity. It demonstrates utility at 1.5 T and offers an easily calculable metric that can be used at the time of scanning or automated to identify on an adaptive basis which patients benefit from dedicated imaging to assess which patients should have additional sequences to assess AS.

Keywords: Aortic Stenosis; Aortic Valve; Balanced Steady-State Free Precession; Left Ventricle; Magnetic Field Strength; Valvular heart disease.

Publication types

  • Multicenter Study
  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aorta / diagnostic imaging
  • Aorta / physiopathology
  • Aortic Valve Stenosis* / diagnostic imaging
  • Aortic Valve Stenosis* / physiopathology
  • Aortic Valve* / abnormalities
  • Aortic Valve* / diagnostic imaging
  • Aortic Valve* / pathology
  • Aortic Valve* / physiopathology
  • Female
  • Heart Ventricles / diagnostic imaging
  • Heart Ventricles / physiopathology
  • Humans
  • Image Interpretation, Computer-Assisted
  • Magnetic Resonance Imaging, Cine*
  • Male
  • Middle Aged
  • Predictive Value of Tests*
  • Regional Blood Flow
  • Reproducibility of Results
  • Retrospective Studies
  • Severity of Illness Index*
  • United States
  • Ventricular Function, Left*