Impact of Procedure Time on First Pass Effect in Mechanical Thrombectomy for Anterior Circulation Acute Ischemic Stroke

Neurosurgery. 2024 Mar 14. doi: 10.1227/neu.0000000000002900. Online ahead of print.

Abstract

Background and objectives: First pass effect (FPE) is a metric increasingly used to determine the success of mechanical thrombectomy (MT) procedures. However, few studies have investigated whether the duration of the procedure can modify the clinical benefit of FPE. We sought to determine whether FPE after MT for anterior circulation large vessel occlusion acute ischemic stroke is modified by procedural time (PT).

Methods: A multicenter, international data set was retrospectively analyzed for anterior circulation large vessel occlusion acute ischemic stroke treated by MT who achieved excellent reperfusion (thrombolysis in cerebral infarction 2c/3). The primary outcome was good functional outcome defined by 90-day modified Rankin scale scores of 0-2. The primary study exposure was first pass success (FPS, 1 pass vs ≥2 passes) and the secondary exposure was PT. We fit-adjusted logistic regression models and used marginal effects to assess the interaction between PT (≤30 vs >30 minutes) and FPS, adjusting for potential confounders including time from stroke presentation.

Results: A total of 1310 patients had excellent reperfusion. These patients were divided into 2 cohorts based on PT: ≤30 minutes (777 patients, 59.3%) and >30 minutes (533 patients, 40.7%). Good functional outcome was observed in 658 patients (50.2%). The interaction term between FPS and PT was significant ( P = .018). Individuals with FPS in ≤30 minutes had 11.5% higher adjusted predicted probability of good outcome compared with those who required ≥2 passes (58.2% vs 46.7%, P = .001). However, there was no significant difference in the adjusted predicted probability of good outcome in individuals with PT >30 minutes. This relationship appeared identical in models with PT treated as a continuous variable.

Conclusion: FPE is modified by PT, with the added clinical benefit lost in longer procedures greater than 30 minutes. A comprehensive metric for MT procedures, namely, FPE 30 , may better represent the ideal of fast, complete reperfusion with a single pass of a thrombectomy device.