Objective: To investigate glucose metrics and identify potential predictors of the achievement of glycemic outcomes in children and adolescents during their first 12 months of MiniMed 780G use.
Research design and methods: This multicenter, longitudinal, real-world study recruited 368 children and adolescents with type 1 diabetes (T1D) starting SmartGuard technology between June 2020 and June 2022. Ambulatory glucose profile data were collected during a 15-day run-in period (baseline), 2 weeks after automatic mode activation, and every 3 months. The influence of covariates on glycemic outcomes after 1 year of MiniMed 780G use was assessed.
Results: After 15 days of automatic mode use, all glucose metrics improved compared with baseline (P < 0.001), except for time below range (P = 0.113) and coefficient of variation (P = 0.330). After 1 year, time in range (TIR) remained significantly higher than at baseline (75.3% vs. 62.8%, P < 0.001). The mean glycated hemoglobin (HbA1c) over the study duration was lower than the previous year (6.9 ± 0.6% vs. 7.4 ± 0.9%, P < 0.001). Time spent in tight range (70-140 mg/dL) was 51.1%, and the glycemia risk index was 27.6. Higher TIR levels were associated with a reduced number of automatic correction boluses (P < 0.001), fewer SmartGuard exits (P = 0.021), and longer time in automatic mode (P = 0.030). Individuals with baseline HbA1c >8% showed more relevant improvement in TIR levels (from 54.3% to 72.3%).
Conclusions: Our study highlights the sustained effectiveness of MiniMed 780G among youth with T1D. Findings suggest that even children and adolescents with low therapeutic engagement may benefit from SmartGuard technology.