Diagnostic yield of implantable loop recorders: results from the hellenic registry

Hellenic J Cardiol. 2024 May 9:S1109-9666(24)00108-8. doi: 10.1016/j.hjc.2024.05.004. Online ahead of print.

Abstract

Objective: Implantable loop recorders (ILRs) are increasingly being used for long-term cardiac monitoring in different clinical settings. The aim of this study was to investigate the real-world performance of ILRs-including the time to diagnosis-in unselected patients with different ILR indications.

Methods and results: In this multicenter, observational study, 871 patients with an indication of pre-syncope/syncope (61.9%), unexplained palpitations (10.4%), and atrial fibrillation (AF) detection with a history of cryptogenic stroke (CS) (27.7%) underwent ILR implantation. The median follow-up was 28.8 ± 12.9 months. In the presyncope/syncope group, 167 (31%) received a diagnosis established by the device. Kaplan-Meier estimates indicated that 16.9% of patients had a diagnosis at 6 months, and the proportion increased to 22.5% at 1 year. Of 91 patients with palpitations, 20 (22%) received a diagnosis based on the device. The diagnosis was established in 12.2% of patients at 6 months, and the proportion increased to 13.3% at 1 year. Among 241 patients with CS, 47 (19.5%) were diagnosed with AF. The diagnostic yield of the device was 10.4% at 6 months and 12.4% at 1 year. In all cases, oral anticoagulation was initiated. Overall, ILR diagnosis altered the therapeutic strategy in 26.1% of the presyncope/syncope group, 2.2% of the palpitations group, and 3.7% of the CS group in addition to oral anticoagulation initiation.

Conclusion: In this real-world patient population, ILR determines diagnosis and initiates new therapeutic management for nearly one-fourth of patients. ILR implantation is valuable in the evaluation of patients with unexplained presyncope/syncope, CS, and palpitations.

Keywords: Atrial fibrillation; Cryptogenic stroke; Implantable loop recorder; Palpitations; Syncope.