Aim: Shear wave (SW) elastography is used to evaluate metabolic dysfunction-associated steatotic liver disease (MASLD) pathophysiology. Increased elasticity due to fibrosis and increased viscosity due to necrosis and inflammation affect SW. Assessing fibrosis, the most prognostically relevant pathology, is critical. Viscosity is evaluated using the dispersion slope (DS); however, cut-off values that affect SW values are unclear. We compared the ultrasound imaging parameters (SW for viscoelasticity; DS for viscosity) with pathological findings.
Methods: Patients (n = 159) who underwent liver biopsy and SW and DS assessments at our hospital were included. Fibrosis stage and inflammation grade cut-off values were calculated from SW, DS, and liver biopsy results using receiver operating characteristic curves. Cases in which liver biopsy results were inconsistent with SW results were used to determine the effect of viscosity on SW values. DS was examined in the Correct and Incorrect Diagnosis groups, which were categorized based on the concordance between SW and liver biopsy results. Dispersion slope cut-off values between the two groups were calculated.
Results: Fibrosis stage cut-off values by SW (m/s) were: ≥F2, 1.62; ≥F3, 1.74; and F4, 1.97. Inflammation grade cut-off values by DS (m/s/kHz) were: ≥A1, 11.6; ≥A2, 14.5; and A3, 16.1. The Correct/Incorrect Diagnosis groups had 25/70 patients. The DS cut-off value for both groups was 13.2 m/s/kHz.
Conclusions: Shear wave and DS are useful for evaluating liver fibrosis and inflammation in MASLD. For DS > 13.2 m/s/kHz, SW may be affected by the increased viscosity owing to inflammation. In such patients, caution should be used when determining/interpreting values.
Keywords: MASLD; dispersion slope; inflammation; liver fibrosis; shear wave.
© 2024 The Author(s). Hepatology Research published by John Wiley & Sons Australia, Ltd on behalf of Japan Society of Hepatology.