T-shaped pars plana scleral incision to remove large intraocular foreign body

Front Med (Lausanne). 2024 May 14:11:1399321. doi: 10.3389/fmed.2024.1399321. eCollection 2024.

Abstract

Aim: To investigate the efficacy and safety profile of T-shaped pars plana scleral incision technique in removing large intraocular foreign bodies, during 23-gauge pars plana vitrectomy.

Methods: Retrospective interventional case series that included patients diagnosed with a large intraocular foreign body (IOFB). Possible postoperative complications were recorded 24 h, 1 month, 3 and 6 months postoperatively.

Results: Thirty eyes of 30 patients (48 ± 5 years old) were enrolled. All IOFBs were successfully removed: mean diameters of 7.8 ± 2.0 mm and 2.6 ± 0.3 mm. Silicone oil and sulfur hexafluoride were used in 27 and 3 eyes, respectively. Lensectomy was performed in 27 eyes. Intraocular lens was implanted at first attempt in 12 eyes; during a second operation in 12 eyes and 6 eyes remained aphakic. At any follow-up, no signs of postoperative complications were observed. Secondary retinal detachment occurred in 12 eyes. Mean preoperative corrected distance visual acuity was 0.04, on the Snellen scale; it increased to 0.07, at last follow-up. Mean intraocular pressure was 17.97 mmHg. All eyes were preserved.

Conclusion: T-shaped scleral incision could be an effective, safe and easy-to-perform standard procedure to remove large IOFBs during pars plana vitrectomy, without increasing the risk of surgical complications and additional damage to the ocular tissues.

Keywords: intraocular foreign body; ocular trauma; pars plana vitrectomy; scleral wound; surgical techinque.

Grants and funding

The author(s) declare that no financial support was received for the research, authorship, and/or publication of this article.