Background and aim: Endoscopic ultrasound-guided gastroenterostomy is a procedure used to connect the stomach and dilated afferent loop using a stent under endoscopic ultrasound for afferent loop syndrome. However, the actual efficacy and safety of this procedure remain unclear. Therefore, this retrospective study aimed to evaluate the efficacy and safety of endoscopic ultrasound-guided gastroenterostomy using a laser-cut-type fully covered self-expandable metallic stent and an anchoring plastic stent for afferent loop syndrome.
Methods: Technical and clinical success rates, adverse events, recurrent intestinal obstruction rates, time to recurrent intestinal obstruction, and technical and clinical success rates of re-intervention were evaluated in intended patients who underwent endoscopic ultrasound-guided gastroenterostomy for afferent loop syndrome from October 2018 to August 2022.
Results: In 25 intended patients with afferent loop syndrome who intended endoscopic ultrasound-guided gastroenterostomy, the technical success rate was 100% (25/25), whereas the clinical success rate was 96% (24/25). Two patients experienced grade ≥ 3 early adverse events, including one with intra-abdominal abscess and one with hypotension. Both events were attributed to intestinal fluid leakage. No late adverse events were observed. The recurrent intestinal obstruction rate was 32% (8/25), and the median time to recurrent intestinal obstruction was 6.5 months (95% confidence interval: 2.8-not available). The technical and clinical success rates of re-intervention were both 100% (8/8).
Conclusions: Endoscopic ultrasound-guided gastroenterostomy using a fully covered self-expandable metallic stent and an anchoring plastic stent is effective and safe as a treatment procedure for afferent loop syndrome.
Keywords: afferent loop syndrome; endoscopic ultrasound‐guided gastroenterostomy; plastic stent; self‐expandable metallic stent.
© 2024 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.