Analysis of hemodynamics and impedance using bioelectrical impedance analysis in hypovolemic shock-induced swine model

Sci Rep. 2024 Jul 2;14(1):15077. doi: 10.1038/s41598-024-65847-y.

Abstract

To treat hypovolemic shock, fluid infusion or blood transfusion is essential to address insufficient volume. Much controversy surrounds resuscitation in hypovolemic shock. We aimed to identify the ideal fluid combination for treating hypovolemic shock-induced swine model, analyzing bioelectrical impedance and hemodynamics. Fifteen female three-way crossbred pigs were divided into three different groups. The three resuscitation fluids were (1) balanced crystalloid, (2) balanced crystalloid + 5% dextrose water, and (3) balanced crystalloid + 20% albumin. The experiment was divided into three phases and conducted sequentially: (1) controlled hemorrhage (1 L bleeding, 60 min), (2) resuscitation phase 1 (1 L fluid infusion, 60 min), and (3) resuscitation phase 2 (1 L fluid infusion, 60 min). Bioelectrical impedance analysis was implemented with a segmental multifrequency bioelectrical impedance analyzer. A total of 61 impedance measurements were assessed for each pig at six different frequencies in five segments of the pig. Pulse rate (PR), mean arterial pressure (MAP), stroke volume (SV), and stroke volume variation (SVV) were measured using a minimally invasive hemodynamic monitoring device. The three-dimensional graph showed a curved pattern when infused with 1 L of balanced crystalloid + 1 L of 5% dextrose water and 1.6 L of balanced crystalloid + 400 ml of 20% albumin. The 1M impedance increased in all groups during the controlled hemorrhage, and continuously decreased from fluid infusion to the end of the experiment. Only balanced crystalloid + 20% albumin significantly restored MAP and SV to the same level as the start of the experiment after the end of fluid infusion. There were no significant differences in MAP and SV from the time of recovery to the initial value of 1M impedance to the end of fluid infusion in all groups. The change and the recovery of hemodynamic indices such as MAP and SV coincide with the change and the recovery of 1M impedance. Using balanced crystalloid mixed with 20% albumin in hypovolemic shock-induced swine model may be helpful in securing hemodynamic stability, compared with balanced crystalloid single administration.

Keywords: Albumin; Bioelectrical impedance; Crystalloid; Hypovolemic shock; Resuscitation.

MeSH terms

  • Albumins
  • Animals
  • Crystalloid Solutions / administration & dosage
  • Disease Models, Animal*
  • Electric Impedance*
  • Female
  • Fluid Therapy* / methods
  • Hemodynamics*
  • Resuscitation / methods
  • Shock* / physiopathology
  • Shock* / therapy
  • Swine

Substances

  • Crystalloid Solutions
  • Albumins