A cross-sectional CBCT assessment of the relative position of one-piece titanium-zirconium mini-implants placed for mandibular overdentures using non-guided surgery

Clin Oral Implants Res. 2024 Nov;35(11):1475-1484. doi: 10.1111/clr.14335. Epub 2024 Jul 23.

Abstract

Objective: To assess the relative position of mini-implants to retain a mandibular overdenture, according to the surgical protocol, technical and anatomical factors.

Methods: Mandibular cone-beam computed tomography (CBCT) scans were analyzed for 73 patients who received four one-piece titanium-zirconium mini-implants. Drilling was performed using a 1.6 mm needle drill and a 2.2 mm Pilot Drill, according to the bone density with a surgical stent. Post-insertion CBCT images in DICOM format were analyzed using the E-Vol-DX software with BAR filters. Divergence angle between implants and between implants and the overdenture path of insertion was measured using CliniView 10.2.6 software.

Results: Divergence between implants ranged from 0° to 22.3° (mean = 4.2; SD = 3.7) in the lateral and from 0° to 26.2° (mean = 5.3; SD = 4.1) in the frontal projections (p < .001). Only 1 (0.2%) and 3 (0.7%) of the measurements were higher than 20° in the lateral and frontal views, respectively. The mean angulations between the implant and the path of insertion for the overdenture were 9.3° (SD = 7.5) and 4.0° (SD = 2.9) for the lateral and frontal views, respectively (p < .001). Regression analyses showed a significant association between the divergence of implants and the frontal view projection (p < .001), greater distance between the paired implants (p = .017), the flapped surgical protocol (p = .002), higher final insertion torque (p = .011), and deeper preparation with the needle drill (p < .001).

Conclusions: The mini-implants were placed with low divergence angles and satisfactory parallelism. Factors including shorter distances between the implants, higher density bone, and a flapless surgical approach all contributed positively to improved parallelism of the mini-implants.

Keywords: cone‐beam computed tomography; dental implant; implant surgery; overdenture.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Cone-Beam Computed Tomography* / methods
  • Cross-Sectional Studies
  • Dental Implantation, Endosseous / methods
  • Dental Implants*
  • Dental Prosthesis, Implant-Supported
  • Denture, Overlay*
  • Female
  • Humans
  • Male
  • Mandible* / diagnostic imaging
  • Mandible* / surgery
  • Middle Aged
  • Titanium*
  • Zirconium*

Substances

  • Titanium
  • Dental Implants
  • Zirconium