Background: Conventional single-energy CT can only provide a raw estimation of electron density (ED) for dose calculation by developing a calibration curve that simply maps the HU values to ED values through their correlations. Spectral CT, also known as dual-energy CT (DECT) or multi-energy CT, can generate a series of quantitative maps, such as ED maps. Using spectral CT for radiotherapy simulations can directly acquire ED information without developing specific calibration curves. The purpose of this study is to assess the feasibility of utilizing electron density (ED) maps generated by a novel dual-layer detector spectral CT simulator for dose calculation in radiotherapy treatment plans.
Methods: 30 patients from head&neck, chest, and pelvic treatment sites were selected retrospectively, and all of them underwent spectral CT simulation. Treatment plans based on conventional CT images were transplanted to ED maps with the same structure set, including planning target volume (PTV) and organs at risk (OARs), and the dose distributions were then recalculated. The differences in dose and volume histogram (DVH) parameters of the PTV and OARs between the two types of plans were analyzed and compared. Besides, gamma analysis between these plans was performed by using MEPHYSTO Navigator software.
Results: In terms of PTV, the homogeneity index (HI), gradient index (GI), D2%, D98%, and Dmean showed no significant difference between conventional plans and ED plans. For OARs, statistically significant differences were observed in parotids D50%, brainstem in head&neck plans, spinal cord in chest plans and rectum D50% in pelvic plans, whereas the variance remained minor. For the rest, the DVH parameters exhibited no significant difference between conventional plans and ED plans. All of the mean gamma passing rates (GPRs) of gamma analysis were higher than 90%.
Conclusion: Compared to conventional treatment plans relying on CT images, plans utilizing ED maps demonstrated similar dosimetric quality. However, the latter approach enables direct utilization in dose calculation without the requirements of establishing and selecting a specific Hounsfield unit (HU) to ED calibration curve, providing an advantage in clinical applications.
Keywords: Dose calculation; Dosimetry comparison; Electronic density; Spectral CT simulator.
© 2024. The Author(s).