Evaluation of parenteral diluent contamination by caprolactam

Am J Health Syst Pharm. 2024 Nov 22;81(23):e770-e776. doi: 10.1093/ajhp/zxae204.

Abstract

Purpose: A leachable cyclic amide (caprolactam) can be found in normal saline (NS) and 5% dextrose in water (D5W) plastic bags widely used in clinical practice if they contain polyamide in a multilayer sheeting. This contamination and the parameters that could influence its content have never been studied in a public work such as a scientific publication.

Methods: Two independent laboratories validated a caprolactam dosing method and studied contamination levels in several containers.

Results: Caprolactam content in multilayer polypropylene/polyamide/polypropylene plastic bags ranged from a mean (SD) of 5.43 (0.21) mg/L (D5W 1,000 mL) to 22.83 (1.26) mg/L (NS 50 mL). NS and D5W can be intravenously administered with a total daily dose of 3 L, corresponding to a minimal daily dose of 16.3 mg of caprolactam.

Conclusion: The high levels of contamination we have reported and the possibility of administering caprolactam to high-risk patients (eg, neonates, the elderly) should make it imperative for pharmaceutical companies to communicate publicly on the safety of caprolactam.

Keywords: HPLC-UV; caprolactam; dextrose; leachable; normal saline; polyamide.

MeSH terms

  • Caprolactam* / analogs & derivatives
  • Caprolactam* / chemistry
  • Drug Contamination* / prevention & control
  • Drug Packaging* / standards
  • Glucose / analysis
  • Humans
  • Nylons / chemistry
  • Polypropylenes / chemistry

Substances

  • Caprolactam
  • Polypropylenes
  • Nylons
  • Glucose