Clinical outcome and intraprocedural characteristics of left atrial appendage occlusion: a comparison between single-occlusive plug-type and dual-occlusive disc-type devices

Front Cardiovasc Med. 2024 Jul 18:11:1401974. doi: 10.3389/fcvm.2024.1401974. eCollection 2024.

Abstract

Background: Percutaneous interventional left atrial appendage occlusion (LAAO) is a reliable, safe, and effective alternative for stroke prevention in selected patients with atrial fibrillation (AF).

Methods: In a retrospective observational study, 149 patients underwent LAAO between 2016 and 2022 at the Department of Cardiology of the Charité-Universitätsmedizin Berlin, Campus Virchow, with AF for prevention of thromboembolic complications. We compared patient characteristics, intraoperative details and postoperative outcomes between single-occlusive plug-type (SOPT) and dual-occlusive disc-type (DODT) devices.

Results: In all patients, the device implantation was successful. 60 patients received a SOPT occluder, including Watchman (35%) and Watchman FLX Occluders (65%), while 89 patients received a DODT occluder, including Amplatzer Cardiac Plug (37.1%), the Amplatzer Amulet (25.8%), and the LAmbre occluder (37.1%) systems. Procedure duration was significantly longer for DODT occluder implantation (49 ± 33 vs. 41 ± 25 min, p = 0.018). There were no in-hospital deaths or thromboembolic events reported after LAAO in both groups. Beyond that, a low rate of bleeding or access-side-related complications and pericardial tamponades were observed. Anticoagulation at discharge varied. About 60.8% of patients received dual antiplatelet therapy at hospital discharge, and 33.1% received direct oral anticoagulants. A 6-month follow-up was obtained in 85% of the patients. All implanted devices were in the desired position. However, in 5.7% of the patients, a device-related thrombus formation was detected in the SOPT group, while no thrombus was seen in the DODT group (p = 0.11). Thromboembolic events were noticed in 3.1%, without any difference between the device types. There was a statistically non-significant trend for less residual device leaks after SOPT vs. DODT implantation (no leak in 71.7% vs. 62.2%, p = 0.07; minor leaks <5 mm, 9.4% vs. 20.3%, p = 0.1). In the SOPT group, less bleeding complications were reported after LAAO (11.3% vs. 17.6%, p = 0.1).

Conclusion: Our data suggest the safety and efficiency of LAAO with a very high procedural implantation success rate irrespective of the used LAA device. Furthermore, no relevant procedural or device-related complication occurred during the 6-month follow-up in all patients.

Keywords: atrial fibrillation (AF); dual-occlusive disc type (DODT); left atrial appendage occlusion (LAAO); oral anticoagulation (OAC); single-occlusive plug type (SOPT); thromboembolic prevention; transient ischemia attack (TIA).

Grants and funding

The authors declare that no financial support was received for the research, authorship, and/or publication of this article.