Establishment of a new vault prediction formula after implantable collamer lens implantation based on factor analysis of multi-modal ophthalmic parameters of anterior and posterior chamber

Clin Exp Ophthalmol. 2024 Dec;52(9):920-933. doi: 10.1111/ceo.14433. Epub 2024 Aug 9.

Abstract

Background: To establish a novel vault prediction formula after implantable collamer lens (ICL) implantation that considers both anterior and posterior chamber characteristics with multi-modal parameters.

Methods: A total of 103 and 65 eyes were included in the development and validation groups, respectively. Exploratory factor analysis was performed using data from optical coherence tomography and ultrasound biomicroscopy in the development group to synthesise summative factors with different clinical significance. Dominant original metrics with heavy loadings on significant factors (absolute value of the loading coefficient >0.5) were screened for multivariate linear regression models using a stepwise method. The newly derived formula was evaluated and compared to the NK and KS formulas in the validation group.

Results: Six factors (anterior chamber angle, horizontal width, lens, iris, iridociliary complex and ciliary body) were generated after dimension reduction via factor analysis. Factors 2 (horizontal width), 3 (lens), and 5 (iridociliary complex) had a significant influence on the vault. When dominant metrics on these factors were screened for further model building, ICL size, anterior chamber width, crystalline lens rise, iris curvature, and iris-ciliary process distance were retained in the final formula, with an adjusted R2 of 0.698, a median absolute error of 81.97 mm, and a root-mean-square error of 103.35 mm.

Conclusions: Multiple intraocular components, including the lens, iris, and ciliary body, play important roles in vault determination. The new formula exhibits good accuracy for vault predictions and ICL size recommendations.

Keywords: anterior chamber; factor analysis; implantable collamer lens (ICL); posterior chamber; vault.

MeSH terms

  • Adult
  • Anterior Chamber* / diagnostic imaging
  • Biometry / methods
  • Ciliary Body / diagnostic imaging
  • Factor Analysis, Statistical
  • Female
  • Humans
  • Iris / diagnostic imaging
  • Lens Implantation, Intraocular*
  • Male
  • Microscopy, Acoustic*
  • Middle Aged
  • Myopia / physiopathology
  • Myopia / surgery
  • Phakic Intraocular Lenses*
  • Posterior Eye Segment / diagnostic imaging
  • Retrospective Studies
  • Tomography, Optical Coherence* / methods
  • Visual Acuity / physiology
  • Young Adult