Background: Screws for graft fixation are available in 3 different materials for anterior cruciate ligament reconstruction (ACLR) with the Tape Locking Screw (TLS) technique: titanium, poly-l-lactic acid bioabsorbable, and polyetheretherketone (PEEK).
Purpose: To compare the effect of the 3 different fixation materials on graft and implant survival after ACLR with the TLS technique.
Study design: Cohort study; Level of evidence, 3.
Methods: Included were 521 patients from the French Prospective ACL Study (FAST) cohort who underwent primary surgical ACLR with the TLS technique. Patients were divided into 3 groups depending on the type of screw material used: titanium (TLS-T group), poly-l-lactic acid bioabsorbable (TLS-B group), or PEEK (TLS-P group). The primary endpoint was a retear within 2 years after ACLR. The secondary endpoints were complication rate, return to sports rate, and functional scores. Objective and subjective functional scores-including the International Knee Documentation Committee, the Knee injury and Osteoarthritis Outcome Score (KOOS), and the Lysholm score-were evaluated preoperatively and at the 2-year follow-up. Pain was assessed with the KOOS-Pain subscore recorded pre- and postoperatively every 6 months up to 2 years. Patient satisfaction was recorded at the 2-year follow-up.
Results: No significant differences between the study groups were found in retear rates (4.4%, 4.5%, and 4.3% in the TLS-T, TLS-P, and TLS-B groups 2 years after surgery) or subjective and objective outcomes. The TLS-T group had the lowest rate of intraoperative implant-related complications (0.9%) compared with the TLS-P (4.3%) and TLS-B (7.7%) groups. Young age was a significant risk factor for retear in the TLS-T (P = .03) and TLS-B (P = .0001) groups, while a high level of sports was found to be a significant risk factor in the TLS-P (P = .04) group. All functional scores improved significantly at the 2-year follow-up (P < .0001), with no significant group difference. The KOOS-Pain subscore improved continuously with no significant group difference. The rate of return to preinjury sports was between 43.4% and 58.6%. The rate of highly satisfied patients at the final follow-up was between 86.2% and 91.8%.
Conclusion: There was no difference in retear rate or objective and subjective functional scores between implant materials for TLS ACLR in this study.
Keywords: Tape Locking Screw; anterior cruciate ligament reconstruction; bioabsorbable; polyetheretherketone; screw material; titanium.
© The Author(s) 2024.