Cost-Utility of Real-Time Continuous Glucose Monitoring versus Self-Monitoring of Blood Glucose in People with Insulin-Treated Type 2 Diabetes in Spain

Clinicoecon Outcomes Res. 2024 Nov 5:16:785-797. doi: 10.2147/CEOR.S483459. eCollection 2024.

Abstract

Objective: Management of advanced type 2 diabetes (T2D) typically involves daily insulin therapy alongside frequent blood glucose monitoring, as treatments such as oral antidiabetic agents are therapeutically insufficient. Real-time continuous glucose monitoring (rt-CGM) has been shown to facilitate greater reductions in glycated hemoglobin (HbA1c) levels and improvements in patient satisfaction relative to self-monitoring of blood glucose (SMBG). This study aimed to investigate the cost-utility of rt-CGM versus SMBG in Spanish patients with insulin-treated T2D..

Methods: The analysis was conducted using the IQVIA Core Diabetes Model (CDM V9.5). Baseline characteristics of the simulated patient cohort and treatment efficacy data were sourced from a large-scale, United States-based retrospective cohort study. Costs were obtained from Spanish sources and inflated to 2022 Euros (EUR) where required. A remaining lifetime horizon (maximum 50 years) was used, alongside an annual discount rate of 3% for future costs and health effects. A willingness-to-pay (WTP) threshold of EUR 30,000 per quality-adjusted life year (QALY) was adopted, based on precedent across previous cost-effectiveness studies set in Spain. A Spanish payer perspective was adopted.

Results: Over patient lifetimes, rt-CGM yielded 9.933 QALYs, versus 8.997 QALYs with SMBG, corresponding to a 0.937 QALY gain with rt-CGM. Total costs in the rt-CGM arm were EUR 2347 higher with rt-CGM versus SMBG (EUR 125,365 versus EUR 123,017). The base case incremental cost-utility ratio was therefore EUR 2506 per QALY gained, substantially lower than the WTP threshold of EUR 30,000 per QALY. The analysis also projected a reduction in cumulative incidence of ophthalmic, renal, neurological, and cardiovascular events in rt-CGM users, with reductions of 16.03%, 13.07%, 7.34%, and 9.09%, respectively.

Conclusion: Compared to SMBG, rt-CGM is highly likely to be a cost-effective intervention for patients living with insulin-treated T2D in Spain.

Keywords: CGM; continuous glucose monitoring; cost-effectiveness; health economics; hypoglycaemia; type 2 diabetes.

Grants and funding

Funding for the analysis, manuscript preparation, and the journal’s article-processing fees was provided by Dexcom.