Improved Detection Accuracy of Chronic Vertebral Compression Fractures by Integrating Height Loss Ratio and Deep Learning Approaches

Diagnostics (Basel). 2024 Nov 6;14(22):2477. doi: 10.3390/diagnostics14222477.

Abstract

Objectives: This study aims to assess the limitations of the height loss ratio (HLR) method and introduce a new approach that integrates a deep learning (DL) model to enhance vertebral compression fracture (VCF) detection performance.

Methods: We conducted a retrospective study on 589 patients with chronic VCFs. We compared four different methods: HLR-only, DL-only, a combination of HLR and DL for positive VCF, and a combination of HLR and DL for negative VCF. The models were evaluated using dice similarity coefficient, sensitivity, specificity, and area under the receiver operating characteristic curve (AUROC).

Results: The combined method (HLR + DL, positive) demonstrated the best performance with an AUROC of 0.968, sensitivity (94.95%), and specificity (90.59%). The HLR-only and the HLR + DL (negative) also showed strong discriminatory power, with AUROCs of 0.948 and 0.947, respectively. The DL-only model achieved the highest specificity (95.92%) but exhibited lower sensitivity (82.83%).

Conclusions: Our study highlights the limitations of the HLR method in detecting chronic VCFs and demonstrates the improved performance of combining HLR with DL models.

Keywords: computed tomography; deep learning; height loss ratio; spine; vertebral compression fracture.

Grants and funding

This work was supported by the Medical AI Clinic Program through the NIPA [H904-24-1007], funded by the MSIT.