Transcatheter mitral valve replacement to treat rheumatic mitral stenosis: a case series

Front Cardiovasc Med. 2024 Dec 5:11:1424105. doi: 10.3389/fcvm.2024.1424105. eCollection 2024.

Abstract

Background: Rheumatic mitral stenosis (RMS) is a common valvular heart disease in developing countries. We sought to evaluate the early experience of patients with RMS undergoing transcatheter mitral valve replacement (TMVR).

Methods: In this retrospective study, a total of 5 RMS patients accepted TMVR. All patients underwent computed tomography and echocardiography before having the procedure. After the preprocedural comprehensive evaluations, the surgeons planned to use the Prizvalve (a novel balloon-expandable transcatheter aortic valve system which is now under the clinical registration study) for TMVR. Clinical data were collected at baseline, before discharge, and at the 30-day follow-up.

Results: The median age of the 5 RMS patients was 61 years (range 60-77 years); 60% were male, and the median Society of Thoracic Surgeons score was 13.3% (range 6.2-17.1%). TMVR was successful in all patients. Postoperative transesophageal echocardiography showed that 60.0% (n = 3) of the patients had no paravalvular leakage and 40.0% (n = 2) had trace paravalvular leakage. The median postoperative peak velocity decreased to 1.4 m/s (range 1.1-1.7 m/s), and the median pressure gradient decreased to 3 mmHg (range 2-3 mmHg). No deaths occurred at the 30-day follow-up, and all patients had an improvement of ≥1 on the New York Heart Association functional rating.

Conclusions: Our early experience with TMVR in RMS patients suggests that it is a safe and feasible procedure. The early results of the procedure are acceptable and provide bright prospects and directions for the precision treatment of RMS.

Clinical trial registration: ClinicalTrials.gov, identifier (NCT02917980).

Keywords: mitral stenosis; mitral valve; prizvalve; rheumatic valvular heart disease; transcatheter mitral valve replacement.

Associated data

  • ClinicalTrials.gov/NCT02917980

Grants and funding

The author(s) declare financial support was received for the research, authorship, and/or publication of this article. This work was supported by the National Key R&D Program of China (2020YFC2008100); the Development and Transformation of New Technology and Construction of Precision Diagnosis and Treatment System for Transcatheter Interventional Diagnosis and Treatment of Structural Heart Diseases (2022YFC2503400); National Natural Science Foundation (82370375); Research on Key Techniques of Minimally Invasive Treatment for Valvular Heart Diseases (2023-YBSF-105); Xijing Hospital Booster Foundation (XJZT24LY42).