Potential of right ventricular function assessment with echocardiography in transcatheter aortic valve replacement

J Cardiothorac Surg. 2024 Dec 30;19(1):686. doi: 10.1186/s13019-024-03198-5.

Abstract

Background: Right ventricular (RV) function assessment by echocardiography can be challenging due to its complex morphology. Also, increasing use of sedation rather than general anesthesia for transfemoral approach transcatheter aortic valve replacement (TAVR) reduces the need for intraoperative transesophageal echocardiography (TEE). Recent clinical studies have demonstrated the importance of 3-dimensional (3D) echocardiography and a longitudinal strain for RV function assessment. In this study, we compared RV function echocardiographic assessment methodologies in TAVR and investigated its clinical utility.

Methods: This was a prospective, observational study of TAVR at a large academic hospital. Inclusion criteria were adult patients undergoing TAVR requiring intraoperative TEE between April 2023 and October 2023. Exclusion criteria include an absolute contraindication to TEE, a pacemaker, or suboptimal intraoperative echocardiography images. The primary goal is to assess the correlation of 3D RV ejection fraction (EF) with RV fraction area change (FAC), and tricuspid annular plane systolic excursion (TAPSE). The secondary goal is to assess the correlation of RV free wall longitudinal strain (FWLS) with any newly diagnosed postoperative ventricular arrhythmia, including complete atrioventricular block (CAVB) and left bundle branch block (LBBB).

Results: Among 33 patients who underwent TAVR, 4 patients were excluded due to poor image quality, and 7 patients were excluded due to existing pacemaker. Thus, data for 22 patients were analyzed in this study. There was a good correlation between 3D RVEF and RV FAC (correlation coefficient 0.789. p = 0.0000482), but poor correlation between 3D RVEF and TAPSE (correlation coefficient 0.182. p = 0.444). Eight patients developed a new left or right BBB and CAVB postoperatively, and 3 patients required permanent pacemaker. Regression analysis of pre and post valve deployment showed RV free wall RVFWLS was each correlated with postoperative new BBB or CAVB (pre valve deployment: hazard ratio 1.272, 95% CI 1.075 to 1.505, p = 0.004981; post valve deployment: hazard ratio 1.134, 95% CI 1.001 to 1.286, p = 0.04846). No mortality was reported during the follow-up period, and no significant tricuspid regurgitation (more than moderate) was reported.

Conclusion: 3D RVEF and RV FAC showed a good correlation. Intraoperative RVFWLS has the potential to predict postoperative new occurrence of BBB or CAVB.

Keywords: Atrioventricular block; Right ventricular function; Speckle track echocardiography; Transcatheter aortic valve replacement.

Publication types

  • Observational Study

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Valve Stenosis / surgery
  • Echocardiography, Three-Dimensional* / methods
  • Echocardiography, Transesophageal / methods
  • Female
  • Heart Ventricles / diagnostic imaging
  • Heart Ventricles / physiopathology
  • Humans
  • Male
  • Prospective Studies
  • Transcatheter Aortic Valve Replacement* / methods
  • Ventricular Function, Right* / physiology