Technetium-99m-Q3 is a myocardial imaging agent that produces prompt myocardial visualization in humans.
Methods: In 19 patients with angiographic coronary artery disease, 2 patients with no angiographic coronary artery stenosis greater than 50% of the luminal diameter and 6 healthy volunteers, exercise and resting myocardial imaging were performed with 99mTc-Q3 and also with 201Tl. Technetium-99m-Q3 imaging began 15 min after injection at rest and with exercise, in a complete imaging sequence that required less than 100 min.
Results: Overall accuracy for coronary disease detection was 78% (21 true-positive or true-negative studies among 27 study participants) by tomographic thallium imaging versus 89% for 99mTc-Q3 tomographic imaging (p = ns). Accuracy for detection of individual coronary stenoses was 75% (61 true-positive or true-negative coronary segment classifications among 81 total coronary segments) for 201Tl imaging and 83% for 99mTc-Q3 imaging (p = ns).
Conclusions: Technetium-99m-Q3 when used in a rest-exercise sequence that can be completed in 100 min appears to provide comparable diagnostic accuracy to 201Tl for overall coronary disease detection and detection of individual coronary artery stenoses.