[Evaluation of the safety and clinical usefulness of a new myocardial imaging agent, 99mTc-PPN1011--multicenter phase II clinical trial report]

Kaku Igaku. 1993 Jan;30(1):25-40.
[Article in Japanese]

Abstract

A new myocardial perfusion imaging agent, 99mTc-1,2-bis[bis(2-ethoxyethyl phosphino]ethane (99mTc-PPN1011) was administered to 52 patients with various heart diseases each at rest and peak exercise on different days (Method A) and on the same day (Method B). The safety, optimal dosage, imaging procedures and the clinical usefulness were evaluated. No drug related adverse reactions were found. Image quality was considered adequate for diagnosis with as little as 185 MBq per injection, though the optimal dose range was 370-740 MBq. SPECT images were obtainable as early as 10 min, also until 3 hours after injection. There were no significant differences in clinical efficacy between method A and B, as well as sequential tests at rest and exercise. 99mTc-PPN1011 and 201T1 images in the same patient were compared segment by segment. Image quality of 99mTc-PPN1011 was significantly superior to that of 201T1. Analysis of images indicated that both agent were similar in diagnostic efficacy. It was concluded that 99mTc-PPN1011 is useful for myocardial perfusion imaging.

Publication types

  • Case Reports
  • Clinical Trial
  • Clinical Trial, Phase II
  • Multicenter Study

MeSH terms

  • Adult
  • Aged
  • Coronary Circulation
  • Coronary Disease / diagnostic imaging*
  • Coronary Disease / physiopathology
  • Heart / diagnostic imaging*
  • Humans
  • Male
  • Middle Aged
  • Organophosphorus Compounds* / standards
  • Organotechnetium Compounds* / standards
  • Tomography, Emission-Computed, Single-Photon

Substances

  • Organophosphorus Compounds
  • Organotechnetium Compounds
  • technetium tc-99m tetrofosmin