Quantitative microculture assays of cryopreserved human immunodeficiency virus type 1-infected cell suspensions and culture supernatants were compared among seven assays sites. There was no significant change in titer during 1 year of storage. The overall standard deviation for infected cell suspensions was approximately 0.8 log10 virus titer. A method for detecting deviant assay results was developed and was used to identify two donor cell preparations (n = 54) that gave consistently low titers.