To investigate the clinical applicability of the three-dimensional (3D) myocardial imaging using a newly developed system (the Application Visualization System-Medical Viewer), thallium-201 myocardial single photon emission computed tomography was performed in 19 patients with previous myocardial infarction before and after treatment with nisoldipine. We have developed a new method for automatically reconstructing 3D imaging for the stereoscopic evaluation of myocardial perfusion. The left ventricular myocardial volume with a radioisotope count > or = 50% of maximum was calculated by using the conventional surface rendering method. With these images, the effect of nisoldipine on myocardial perfusion was assessed and the myocardial volume with a radioisotope count > or = 50% of maximum was compared. In fifteen (88%) of 19 patients, myocardial perfusion increased in the infarct areas after nisoldipine treatment. Nisoldipine significantly increased the myocardial volume with a radioisotope count > or = 50% of maximum from 141 +/- 17 to 153 +/- 18 ml on the stress 3D imagings. These findings indicate that nisoldipine improved myocardial perfusion during exercise. 3D imaging provided stereoscopic assessment of the changes in myocardial perfusion following treatment with nisoldipine and also detected transient enlargement of the left ventricular lumen induced by exercise.