Purpose: To assess the usefulness of cine-magnetic resonance imaging (cine-MRI)in the evaluation of chest wall invasion, we compared the results of cine-MRI with those of computed tomography (CT) and ultrasonography (US).
Materials and methods: Eleven patients were examined who had no pain and who were difficult to diagnose by routine examinations. MRI was performed with a Magnetom SP/4000, 1.5T unit (Siemens, Germany). For cine imaging, continuous turbo-FLUSH (ultra fast low angle shot) images were obtained at an orthogonal section to the chest wall during slow deep breathing. A CT scan was performed using a TCT 900S or Super Helix (Toshiba, Japan) at 1 cm intervals, with section thicknesses of 1 cm throughout the entire chest. US was performed with a model SSA-270A (Toshiba, Japan) with 7.5-MHz linear array scanners (PLF-705S; Toshiba, Japan).
Results: Sensitivity, specificity and accuracy were 67%, 75% and 73% for cine MRI, 67%, 63% and 64% for CT, 33%, 75% and 64% for US, respectively.