This study presents the development of a kit formulation for the preparation of 99mTc-DMP-HSA, followed by a comparison of such kit-prepared 99mTc-DMP-HSA to 99mTc-RBCs in a volunteer. Reconstitution of the labeling kits with up to 5.55 GBq 99mTc afforded 99mTc-DMP-HSA preparations with a > 95% radiochemical purity for up to 8 h. Only minor differences were observed in the global distribution of both tracer agents, whereas the calculated ejection fractions were almost identical. The effective dose equivalent of 99mTc-DMP-HSA is 8.68 microSv/MBq.