Stenting of nonacute total coronary occlusions: predictors of late angiographic outcome

J Am Coll Cardiol. 1998 Feb;31(2):275-80. doi: 10.1016/s0735-1097(97)00501-9.

Abstract

Objectives: This study was designed to determine and assess factors predictive of the intermediate-term outcome of stenting of nonacute total coronary occlusions.

Background: Balloon angioplasty of recanalized coronary occlusions is associated with a combined restenosis/reocclusion rate of up to 65%. Adjunctive stenting holds the potential to reduce this rate significantly. However, variables affecting the late angiographic outcome of coronary stenting in the setting of a total occlusion have not been elucidated sufficiently.

Methods: Coronary stenting was performed in 143 consecutive patients with a nonacute total occlusion; 120 of these patients (84%), with a total of 121 occlusions, underwent repeat angiography within 6 months and comprised the study group. High pressure stent implantation aimed to cover the site of the occlusion as well as adjacent diameter stenoses > or = 70% and all possibly induced dissections. Pertinent angiographic and procedural variables obtained at the time of the intervention were entered into a multivariate logistic regression analysis model to assess their influence on the angiographic outcome at follow-up.

Results: Mean preinterventional reference lumen diameter for the 121 vessels was 2.99 +/- 0.53 mm (mean +/- SD); occlusion length ranged from 4 to 44 mm (median of 7.7). After balloon angioplasty, dissections were found in 80% of patients. Lesions were covered with stents a median of 16 mm in length (range 8 to 53). The minimal lumen diameter (MLD) achieved after stenting was 2.89 +/- 0.48 mm. After a median follow-up period of 4.5 months, mean MLD was assessed at 1.91 +/- 0.90 mm, corresponding to a loss index of 0.34 +/- 0.31. There were 27 vessels with a nonocclusive restenosis > or = 50% and 8 with a reocclusion, for a combined restenosis/reocclusion rate of 29%. Factors found to adversely influence angiographic outcome were a post-stenting MLD < or = 2.54 mm, a stented vessel segment length > 16 mm, a balloon/vessel diameter ratio for final stent expansion < or = 1.00 and the presence of a dissection after balloon angioplasty.

Conclusions: Compared with previous reports on stand-alone balloon angioplasty, stenting of nonacute total coronary occlusions lowers the 6-month restenosis/reocclusion rate to approximately 30%. The late procedural outcome is independently and statistically significantly influenced by the MLD after stenting, the length of the stented vessel segment, the balloon/vessel diameter ratio for final stent expansion and the incidence of dissections after balloon angioplasty.

Publication types

  • Comparative Study

MeSH terms

  • Analysis of Variance
  • Angioplasty, Balloon, Coronary / adverse effects
  • Aortic Dissection / etiology
  • Aortic Dissection / therapy
  • Chi-Square Distribution
  • Cohort Studies
  • Coronary Aneurysm / etiology
  • Coronary Aneurysm / therapy
  • Coronary Angiography*
  • Coronary Disease / diagnostic imaging
  • Coronary Disease / pathology
  • Coronary Disease / therapy*
  • Coronary Vessels / pathology
  • Female
  • Follow-Up Studies
  • Forecasting
  • Humans
  • Incidence
  • Logistic Models
  • Male
  • Middle Aged
  • Multivariate Analysis
  • Recurrence
  • Risk Factors
  • Stents*
  • Treatment Outcome
  • Vascular Patency