Recurrent deep venous thrombosis complicating PICC line placement in two patients with cystic fibrosis and activated protein C-resistance

Pediatr Radiol. 1998 Jul;28(7):552-3. doi: 10.1007/s002470050411.

Abstract

Two patients with cystic fibrosis and activated protein C-resistance experienced deep vein thrombosis complicating peripherally inserted central catheter (PICC) use. Cystic fibrosis patients may be at increased risk for catheter rotated thrombosis.

Publication types

  • Case Reports

MeSH terms

  • Adolescent
  • Adult
  • Arm / blood supply
  • Catheterization, Peripheral / adverse effects*
  • Cystic Fibrosis / complications
  • Cystic Fibrosis / therapy*
  • Factor V / genetics
  • Female
  • Humans
  • Protein C / metabolism*
  • Recurrence
  • Subclavian Vein*
  • Thrombophilia / complications*
  • Thrombosis / etiology*

Substances

  • Protein C
  • factor V Leiden
  • Factor V