Improved collection of mobilized CD34+ hematopoietic progenitor cells by a novel automated leukapheresis system

Transfusion. 1999 Jan;39(1):48-55. doi: 10.1046/j.1537-2995.1999.39199116894.x.

Abstract

Background: For simplification of blood cell transplantation, an automated apheresis system that exploits a dual-stage channel device for mononuclear cell (MNC) collection (AutoPBSC, designed for the COBE Spectra) was studied.

Study design and methods: The automated default software (AutoPBSC-Default) and three software modifications of the harvest frequency during leukapheresis, referred to as AutoPBSC-1.25, AutoPBSC-1.75, and AutoPBSC-2.75, were evaluated in comparison with the semiautomated Version 4.7 (V4.7) apheresis system in 119 leukapheresis procedures performed in 90 cancer patients treated with chemotherapy plus granulocyte-colony-stimulating factor. CD34+ cell and platelet collection efficiency (CE); volume and cell composition of the leukapheresis components; and patient platelet and red cell (RBC) loss during leukapheresis were measured.

Results: The majority of collection measures evaluated with the AutoPBSC compared favorably to those obtained with the V4.7. CD34+ cell CE increased from 55 percent with V4.7 to 68 percent with the AutoPBSC-Default (p = 0.05). The AutoPBSC provided lower platelet contamination in the collected component (1.18 x 10(11) vs. 2.26 x 10(11) with the V4.7; p<0.001). The volume of the AutoPBSC-Default component was significantly lower (67 vs. 180 mL with the V4.7; p<0.001). The MNC purity of the AutoPBSC component was greater (52 vs. 28% with the V4.7; p<0.001), and the RBC contamination lower (AutoPBSC, 0.53 x 10(11) vs. 1.04 x 10(11) with the V4.7; p<0.001). Modifications of the AutoPBSC to increase the harvest frequency by 1.25-, 1.75-, and 2.75-fold resulted in increased CD34+ cell CE (77%, 75%, and 83%, respectively; p<0.001 in all cases), but also in reduced numbers of circulating platelets, higher platelet contamination of the component, and lower MNC purity than were seen with the AutoPBSC-Default.

Conclusion: The AutoPBSC offers the following advantages over the V4.7 system: a) better CE of CD34+ cells; b) reduced collection of platelets; c) reduced contamination of the leukapheresis component with granulocytes, platelets, and RBCs; d) reduced component volume; and e) automation.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adolescent
  • Adult
  • Antigens, CD34 / blood*
  • Blood Specimen Collection / standards
  • Child
  • Female
  • Hematopoietic Stem Cells / immunology*
  • Humans
  • Leukapheresis / adverse effects
  • Leukapheresis / methods*
  • Male
  • Middle Aged
  • Neoplasms / therapy
  • Software

Substances

  • Antigens, CD34