Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My Custom Filters

Publication date

Text availability

Article attribute

Article type

Additional filters

Article Language

Species

Sex

Age

Other

Search Results

45 results

Filters applied: . Clear all
Results are displayed in a computed author sort order. The Publication Date timeline is not available.
Page 1
PCO2 affects tracheal tone during apnea in anesthetized dogs.
Dickstein J, Greenberg A, Kruger J, Robicsek A, Silverman JA, Sommer LZ, Sommer DD, Volgyesi GA, Iscoe S, Fisher JA. Dickstein J, et al. Among authors: volgyesi ga. J Appl Physiol (1985). 1996 Sep;81(3):1184-9. doi: 10.1152/jappl.1996.81.3.1184. J Appl Physiol (1985). 1996. PMID: 8889752
Tracheal constrictor drive above the apneic threshold in anesthetized dogs.
Silverman JA, Sommer LZ, Robicsek A, Dickstein J, Greenberg A, Kruger J, Rucker J, Volgyesi G, Fisher JA, Iscoe S. Silverman JA, et al. J Appl Physiol (1985). 2000 Dec;89(6):2258-62. doi: 10.1152/jappl.2000.89.6.2258. J Appl Physiol (1985). 2000. PMID: 11090576 Free article.
Dynamic measurement of tracheal diameter in dogs.
Fisher JA, Volgyesi G, Sommer DD, Silverman JA, Fink AK, Robicsek AA, Sommer LZ. Fisher JA, et al. J Appl Physiol (1985). 1995 Feb;78(2):388-93. doi: 10.1152/jappl.1995.78.2.388. J Appl Physiol (1985). 1995. PMID: 7759406
Isocapnic hyperpnea accelerates carbon monoxide elimination.
Fisher JA, Rucker J, Sommer LZ, Vesely A, Lavine E, Greenwald Y, Volgyesi G, Fedorko L, Iscoe S. Fisher JA, et al. Am J Respir Crit Care Med. 1999 Apr;159(4 Pt 1):1289-92. doi: 10.1164/ajrccm.159.4.9804040. Am J Respir Crit Care Med. 1999. PMID: 10194179
A simple "new" method to accelerate clearance of carbon monoxide.
Takeuchi A, Vesely A, Rucker J, Sommer LZ, Tesler J, Lavine E, Slutsky AS, Maleck WH, Volgyesi G, Fedorko L, Iscoe S, Fisher JA. Takeuchi A, et al. Am J Respir Crit Care Med. 2000 Jun;161(6):1816-9. doi: 10.1164/ajrccm.161.6.9907038. Am J Respir Crit Care Med. 2000. PMID: 10852750 Clinical Trial.
Evaluation of a new pulse oximeter testing device.
Fisher JA, Martire T, Volgyesi GA. Fisher JA, et al. Among authors: volgyesi ga. Can J Anaesth. 1996 Feb;43(2):179-83. doi: 10.1007/BF03011260. Can J Anaesth. 1996. PMID: 8825544
Prospective targeting and control of end-tidal CO2 and O2 concentrations.
Slessarev M, Han J, Mardimae A, Prisman E, Preiss D, Volgyesi G, Ansel C, Duffin J, Fisher JA. Slessarev M, et al. J Physiol. 2007 Jun 15;581(Pt 3):1207-19. doi: 10.1113/jphysiol.2007.129395. Epub 2007 Apr 19. J Physiol. 2007. PMID: 17446225 Free PMC article.
45 results