Sign in to use this feature.

Years

Between: -

Search Results (6,908)

Search Parameters:
Keywords = biosensor

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
25 pages, 4163 KiB  
Review
The Evolution of Illicit-Drug Detection: From Conventional Approaches to Cutting-Edge Immunosensors—A Comprehensive Review
by Nigar Anzar, Shariq Suleman, Yashda Singh, Supriya Kumari, Suhel Parvez, Roberto Pilloton and Jagriti Narang
Biosensors 2024, 14(10), 477; https://doi.org/10.3390/bios14100477 - 3 Oct 2024
Viewed by 277
Abstract
The increasing use of illicit drugs has become a major global concern. Illicit drugs interact with the brain and the body altering an individual’s mood and behavior. As the substance-of-abuse (SOA) crisis continues to spread across the world, in order to reduce trafficking [...] Read more.
The increasing use of illicit drugs has become a major global concern. Illicit drugs interact with the brain and the body altering an individual’s mood and behavior. As the substance-of-abuse (SOA) crisis continues to spread across the world, in order to reduce trafficking and unlawful activity, it is important to use point-of-care devices like biosensors. Currently, there are certain conventional detection methods, which include gas chromatography (GC), mass spectrometry (MS), surface ionization, surface-enhanced Raman spectroscopy (SERS), surface plasmon resonance (SPR), electrochemiluminescence (ECL), high-performance liquid chromatography (HPLC), etc., for the detection of abused drugs. These methods have the advantage of high accuracy and sensitivity but are generally laborious, expensive, and require trained operators, along with high sample requirements, and they are not suitable for on-site drug detection scenarios. As a result, there is an urgent need for point-of-care technologies for a variety of drugs that can replace conventional techniques, such as a biosensor, specifically an immunosensor. An immunosensor is an analytical device that integrates an antibody-based recognition element with a transducer to detect specific molecules (antigens). In an immunosensor, the highly selective antigen–antibody interaction is used to identify and quantify the target analyte. The binding event between the antibody and antigen is converted by the transducer into a measurable signal, such as electrical, optical, or electrochemical, which corresponds to the presence and concentration of the analyte in the sample. This paper provides a comprehensive overview of various illicit drugs, the conventional methods employed for their detection, and the advantages of immunosensors over conventional techniques. It highlights the critical need for on-site detection and explores emerging point-of-care testing methods. The paper also outlines future research goals in this field, emphasizing the potential of advanced technologies to enhance the accuracy, efficiency, and convenience of drug detection. Full article
(This article belongs to the Special Issue Feature Paper in Biosensor and Bioelectronic Devices 2024)
15 pages, 3519 KiB  
Article
A Double-Stranded Aptamer for Highly Sensitive Fluorescent Detection of Glutathione S-Transferases
by Wei Cui, Suping Li, Jiahao Zeng, Chen Li, Zhaofeng Li, Xiaohong Wen, Suxia Bao, Yang Mei, Xiangxian Meng and Qiuping Guo
Biosensors 2024, 14(10), 476; https://doi.org/10.3390/bios14100476 - 3 Oct 2024
Viewed by 213
Abstract
Aptamer-based biosensors have been widely constructed and applied to detect diverse targets. Glutathione S-transferase (GST), a pivotal phase II metabolic enzyme, plays a critical role in biotransformation in vivo, and aberrant GST expression is associated with various health risks. Herein, aptamers targeting GST [...] Read more.
Aptamer-based biosensors have been widely constructed and applied to detect diverse targets. Glutathione S-transferase (GST), a pivotal phase II metabolic enzyme, plays a critical role in biotransformation in vivo, and aberrant GST expression is associated with various health risks. Herein, aptamers targeting GST were systematically selected from a randomized single-stranded DNA (ssDNA) library of 79 nucleotides (nt) using a biotinylated GST-immobilized streptavidin agarose (SA) bead SELEX technology. Following rigorous screening across eight rounds, four aptamers with strikingly similar secondary structures emerged. Among these, Seq3 exhibited the highest affinity towards GST and was selected for further optimization. A semi-rational post-SELEX truncation strategy was then employed based on base composition analysis, secondary structure analysis and affinity assessment. This strategy enabled the systematic removal of redundant nucleotides in Seq3 without compromising its affinity, ultimately yielding a truncated aptamer, Seq3-3, which retains its specificity with a compact 39nt length. Building upon Seq3-3, a double-stranded fluorescent aptamer probe was ingeniously designed for the in vitro detection of GST. The detection mechanism hinges on the competitive displacement of the complementary chain from the probe, mediated by the target protein, leading to the separation of the antisense oligonucleotide from the double-stranded complex. This process triggers the restoration of the fluorescence signal, enabling sensitive detection, and the probe exhibits excellent response within a linear range of GST activity ranging from 0 to 1500 U/L. The results show that not only an efficient strategy for screening robust and practicable aptamers but also an ultrahighly sensitive detection platform for GST was established. Full article
Show Figures

Graphical abstract

12 pages, 2670 KiB  
Article
A Zinc Oxide Nanorod-Based Electrochemical Aptasensor for the Detection of Tumor Markers in Saliva
by Junrong Li, Yihao Ding, Yuxuan Shi, Zhiying Liu, Jun Lin, Rui Cao, Miaomiao Wang, Yushuo Tan, Xiaolin Zong, Zhan Qu, Liping Du and Chunsheng Wu
Chemosensors 2024, 12(10), 203; https://doi.org/10.3390/chemosensors12100203 - 2 Oct 2024
Viewed by 242
Abstract
Biosensors have emerged as a promising tool for the early detection of oral squamous cell carcinoma (OSCC) due to their rapid, sensitive, and specific detection of cancer biomarkers. Saliva is a non-invasive and easy-to-obtain biofluid that contains various biomarkers of OSCC, including the [...] Read more.
Biosensors have emerged as a promising tool for the early detection of oral squamous cell carcinoma (OSCC) due to their rapid, sensitive, and specific detection of cancer biomarkers. Saliva is a non-invasive and easy-to-obtain biofluid that contains various biomarkers of OSCC, including the carcinoembryonic antigen (CEA). In this study, an electrochemical aptasensor for the detection of CEA in saliva has been developed towards the diagnosis and early screening of OSCC. This aptasensor utilized a CEA-sensitive aptamer as sensitive elements. A fluorine-doped Tin Oxide (FTO) chip with a surface modification of a zinc oxide nanorod was employed as a transducer. Electrochemical measurements were carried out to detect the responsive signals originating from the specific binding between aptamers and CEAs. The measurement results indicated that this aptasensor was responsive to different concentrations of CEA ranging from 1 ng/mL to 80 ng/mL in a linear relationship. The limit of detection (LOD) was 0.75 ng/mL. This aptasensor also showed very good specificity and regenerative capability. Stability testing over a 12-day period showed excellent performance of this aptasensor. All the results demonstrated that this aptasensor has great potential to be used for the detection of CEA in the saliva of OSCC patients. This aptasensor provides a promising method for the rapid detection of CEA with convenience, which has great potential to be used as a new method for clinical diagnoses and early screening of OSCC. Full article
(This article belongs to the Special Issue Chemical and Biosensors Based on Metal-Organic Frames (MOFs))
Show Figures

Figure 1

12 pages, 2122 KiB  
Article
A Nanoparticle-Coated Cellulose Acetate Membrane for Highly Efficient, Low-Cost Circulating Tumor Cell Detection
by Yize Zhao, Yaqi Pan, Hao Sun, Pengfei Huo, Guangtong Wang and Shaoqin Liu
Biosensors 2024, 14(10), 472; https://doi.org/10.3390/bios14100472 - 1 Oct 2024
Viewed by 346
Abstract
Detecting circulating tumor cells has exhibited great significance in treating cancers since its concentration is an index strongly associated with the development and transfer of the tumor. However, the present commercial method for CTC detection is still expensive, because special antibodies and complicated [...] Read more.
Detecting circulating tumor cells has exhibited great significance in treating cancers since its concentration is an index strongly associated with the development and transfer of the tumor. However, the present commercial method for CTC detection is still expensive, because special antibodies and complicated devices must be used for cell separation and imaging. Hence, it is quite necessary to apply alternative materials and methods to decrease the cost of CTC detection. In this article, we coated a cellulose acetate membrane with nanoparticles formed by the polymerization of melamine and furfural, creating a surface with nanoscale roughness for the highly efficient capture of the sparse CTCs in a blood sample. Subsequently, the CTCs on the surface can be quantitatively detected by colorimetry with the aid of a COF-based nanozyme. The detection limit (LOD) can be as low as 3 cells/mL, which is the lowest LOD among the colorimetric methods to our knowledge. Considering the low cost of fabricating the membrane for CTC capture and the robustness of nanozymes compared with natural enzymes, this CTC detection approach displays great potential to decrease the financial burden of commercial CTC detection. Full article
21 pages, 2235 KiB  
Article
Challenges and Solutions for Leave-One-Out Biosensor Design in the Context of a Rugged Fitness Landscape
by Shounak Banerjee, Keith Fraser, Donna E. Crone, Jinal C. Patel, Sarah E. Bondos and Christopher Bystroff
Sensors 2024, 24(19), 6380; https://doi.org/10.3390/s24196380 - 1 Oct 2024
Viewed by 285
Abstract
The leave-one-out (LOO) green fluorescent protein (GFP) approach to biosensor design combines computational protein design with split protein reconstitution. LOO-GFPs reversibly fold and gain fluorescence upon encountering the target peptide, which can be redefined by computational design of the LOO site. Such an [...] Read more.
The leave-one-out (LOO) green fluorescent protein (GFP) approach to biosensor design combines computational protein design with split protein reconstitution. LOO-GFPs reversibly fold and gain fluorescence upon encountering the target peptide, which can be redefined by computational design of the LOO site. Such an approach can be used to create reusable biosensors for the early detection of emerging biological threats. Enlightening biophysical inferences for nine LOO-GFP biosensor libraries are presented, with target sequences from dengue, influenza, or HIV, replacing beta strands 7, 8, or 11. An initially low hit rate was traced to components of the energy function, manifesting in the over-rewarding of over-tight side chain packing. Also, screening by colony picking required a low library complexity, but designing a biosensor against a peptide of at least 12 residues requires a high-complexity library. This double-bind was solved using a “piecemeal” iterative design strategy. Also, designed LOO-GFPs fluoresced in the unbound state due to unwanted dimerization, but this was solved by fusing a fully functional prototype LOO-GFP to a fiber-forming protein, Drosophila ultrabithorax, creating a biosensor fiber. One influenza hemagglutinin biosensor is characterized here in detail, showing a shifted excitation/emission spectrum, a micromolar affinity for the target peptide, and an unexpected photo-switching ability. Full article
(This article belongs to the Special Issue Fluorescence Sensors for Biological and Medical Applications)
17 pages, 1008 KiB  
Article
Application of Surface Plasmon Resonance Imaging Biosensors for Determination of Fibronectin, Laminin-5, and Type IV Collagen in Plasma, Urine, and Tissue of Renal Cell Carcinoma
by Tomasz Guszcz, Anna Sankiewicz, Lech Gałek, Ewelina Chilinska-Kopko, Adam Hermanowicz and Ewa Gorodkiewicz
Sensors 2024, 24(19), 6371; https://doi.org/10.3390/s24196371 - 30 Sep 2024
Viewed by 394
Abstract
Laminin, fibronectin, and collagen IV are pivotal extracellular matrix (ECM) components. The ECM environment governs the fundamental properties of tumors, including proliferation, vascularization, and invasion. Given the critical role of cell-matrix adhesion in malignant tumor progression, we hypothesize that the concentrations of these [...] Read more.
Laminin, fibronectin, and collagen IV are pivotal extracellular matrix (ECM) components. The ECM environment governs the fundamental properties of tumors, including proliferation, vascularization, and invasion. Given the critical role of cell-matrix adhesion in malignant tumor progression, we hypothesize that the concentrations of these proteins may be altered in the plasma of patients with clear cell renal cell carcinoma (ccRCC). This study aimed to evaluate the serum, urine, and tissue levels of laminin-5, collagen IV, and fibronectin among a control group and ccRCC patients, with the latter divided into stages T1–T2 and T3–T4 according to the TNM classification. We included 60 patients with histopathologically confirmed ccRCC and 26 patients diagnosed with chronic cystitis or benign prostatic hyperplasia (BPH). Collagen IV, laminin-5, and fibronectin were detected using Surface Plasmon Resonance Imaging biosensors. Significant differences were observed between the control group and ccRCC patients, as well as between the T1–T2 and T3–T4 subgroups. Levels were generally higher in plasma and tissue for fibronectin and collagen IV in ccRCC patients and lower for laminin. The ROC (Receiver operating characteristic) analysis yielded satisfactory results for differentiating between ccRCC patients and controls (AUC 0.84–0.93), with statistical significance for both fibronectin and laminin in plasma and urine. Analysis between the T1–T2 and T3–T4 groups revealed interesting findings for all examined substances in plasma (AUC 0.8–0.95). The results suggest a positive correlation between fibronectin and collagen levels and ccRCC staging, while laminin shows a negative correlation, implying a potential protective role. The relationship between plasma and urine concentrations of these biomarkers may be instrumental for tumor detection and staging, thereby streamlining therapeutic decision-making. Full article
(This article belongs to the Special Issue Recent Advances in Plasmon Resonance Sensors)
19 pages, 3827 KiB  
Review
Diamond FET Biosensor Fabrication and Application
by Fengling Zou, Zimin Wang, Zelong Lin, Chengyong Wang and Zhishan Yuan
Electronics 2024, 13(19), 3881; https://doi.org/10.3390/electronics13193881 - 30 Sep 2024
Viewed by 308
Abstract
Diamond is renowned as the ultimate semiconductor thanks to its exceptional physical properties, including unmatched hardness, exceptional wear resistance, superior mechanical and tribological characteristics, and high fracture strength. Diamond solution-gate field-effect transistors (D-SGFETs) leverage these advantages, along with their outstanding high-power and high-frequency [...] Read more.
Diamond is renowned as the ultimate semiconductor thanks to its exceptional physical properties, including unmatched hardness, exceptional wear resistance, superior mechanical and tribological characteristics, and high fracture strength. Diamond solution-gate field-effect transistors (D-SGFETs) leverage these advantages, along with their outstanding high-power and high-frequency performance, excellent thermal conductivity, wide bandgap, high carrier mobility, and rapid saturation speed. These features make D-SGFETs highly promising for fast and precise biomedical detection applications. This paper provides a comprehensive review of the fabrication techniques for diamond SGFETs, encompassing diamond film synthesis, surface conduction layer formation, source/drain fabrication, and FET packaging. Furthermore, the study delves into the surface functionalization of diamond SGFETs and their diverse applications in biomedical detection. Finally, the paper discusses the future outlook of diamond SGFETs in advancing biomedical detection technologies. Full article
(This article belongs to the Section Bioelectronics)
Show Figures

Figure 1

11 pages, 1930 KiB  
Article
Aptamer-Mediated Electrochemical Detection of SARS-CoV-2 Nucleocapsid Protein in Saliva
by Ryan H. P. Siu, Robert G. Jesky, Yu-Jing Fan, Cyrus C. H. Au-Yeung, Andrew B. Kinghorn, Kwok-Hung Chan, Ivan Fan-Ngai Hung and Julian A. Tanner
Biosensors 2024, 14(10), 471; https://doi.org/10.3390/bios14100471 - 30 Sep 2024
Viewed by 385
Abstract
Gold standard detection of SARS-CoV-2 by reverse transcription quantitative PCR (RT-qPCR) can achieve ultrasensitive viral detection down to a few RNA copies per sample. Yet, the lengthy detection and labor-intensive protocol limit its effectiveness in community screening. In view of this, a structural [...] Read more.
Gold standard detection of SARS-CoV-2 by reverse transcription quantitative PCR (RT-qPCR) can achieve ultrasensitive viral detection down to a few RNA copies per sample. Yet, the lengthy detection and labor-intensive protocol limit its effectiveness in community screening. In view of this, a structural switching electrochemical aptamer-based biosensor (E-AB) targeting the SARS-CoV-2 nucleocapsid (N) protein was developed. Four N protein-targeting aptamers were characterized on an electrochemical cell configuration using square wave voltammetry (SWV). The sensor was investigated in an artificial saliva matrix optimizing the aptamer anchoring orientation, SWV interrogation frequency, and target incubation time. Rapid detection of the N protein was achieved within 5 min at a low nanomolar limit of detection (LOD) with high specificity. Specific N protein detection was also achieved in simulated positive saliva samples, demonstrating its feasibility for saliva-based rapid diagnosis. Further research will incorporate novel signal amplification strategies to improve sensitivity for early diagnosis. Full article
Show Figures

Graphical abstract

10 pages, 3726 KiB  
Article
Needle Tip Tracking through Photoluminescence for Minimally Invasive Surgery
by Meenakshi Narayan and Mithun Bhowmick
Biosensors 2024, 14(10), 470; https://doi.org/10.3390/bios14100470 - 30 Sep 2024
Viewed by 246
Abstract
Minimally invasive surgery continues to prioritize patient safety by improving imaging techniques and tumor detection methods. In this work, an all-optical alternative to the current image based techniques for in vitro minimally invasive procedures has been explored. The technique uses a highly fluorescent [...] Read more.
Minimally invasive surgery continues to prioritize patient safety by improving imaging techniques and tumor detection methods. In this work, an all-optical alternative to the current image based techniques for in vitro minimally invasive procedures has been explored. The technique uses a highly fluorescent marker for the surgical needle to be tracked inside simulated tissues. A series of markers were explored including inorganic (Perovskite and PbS) and organic (carbon dots) nanoparticles and organic dye (Rhodamine 6G) to identify layers of different stiffnesses within a tissue. Rhodamine 6G was chosen based on its high fluorescence signal to track 3D position of a surgical needle in a tissue. The needle was tracked inside homogeneous and inhomogeneous gelatin tissues successfully. This exploratory study of tissue characterization and needle tip tracking using fluorescent markers or photoluminescence technique show potential for real-time application of robot-assisted needle insertions during in vivo procedures. Full article
Show Figures

Figure 1

15 pages, 3317 KiB  
Article
A Label-Free Electrochemical Aptamer Sensor for Sensitive Detection of Cardiac Troponin I Based on AuNPs/PB/PS/GCE
by Liying Jiang, Dongyang Li, Mingxing Su, Yirong Qiu, Fenghua Chen, Xiaomei Qin, Lan Wang, Yanghai Gui, Jianbo Zhao, Huishi Guo, Xiaoyun Qin and Zhen Zhang
Nanomaterials 2024, 14(19), 1579; https://doi.org/10.3390/nano14191579 - 30 Sep 2024
Viewed by 363
Abstract
Cardiac troponin I (cTnI) monitoring is of great value in the clinical diagnosis of acute myocardial infarction (AMI). In this paper, a highly sensitive electrochemical aptamer sensor using polystyrene (PS) microspheres as the electrode substrate material in combination with Prussian blue (PB) and [...] Read more.
Cardiac troponin I (cTnI) monitoring is of great value in the clinical diagnosis of acute myocardial infarction (AMI). In this paper, a highly sensitive electrochemical aptamer sensor using polystyrene (PS) microspheres as the electrode substrate material in combination with Prussian blue (PB) and gold nanoparticles (AuNPs) was demonstrated for the sensitive and label-free determination of cTnI. PS microspheres were synthesized by emulsion polymerization and then dropped onto the glassy carbon electrode (GCE); PB and AuNPs were electrodeposited on the electrode in corresponding electrolyte solutions step by step. The PS microsphere substrate provided a large surface area for the loading mass of the biological affinity aptamers, while the PB layer improved the electrical conductivity of the modified electrode, and the electroactive AuNPs exhibited excellent catalytic performance for the subsequent electrochemical measurements. In view of the above mentioned AuNPs/PB/PS/GCE sensing platform, the fabricated label-free electrochemical aptamer sensor exhibited a wide detection range of 10 fg/mL~1.0 μg/mL and a low detection limit of 2.03 fg/mL under the optimal conditions. Furthermore, this biosensor provided an effective detection platform for the analysis of cTnI in serum samples. The introduction of this sensitive electrochemical aptamer sensor provides a reference for clinically sensitive detection of cTnI. Full article
Show Figures

Figure 1

24 pages, 8540 KiB  
Review
A Review of Advanced Sensor Technologies for Aquatic Products Freshness Assessment in Cold Chain Logistics
by Baichuan Wang, Kang Liu, Guangfen Wei, Aixiang He, Weifu Kong and Xiaoshuan Zhang
Biosensors 2024, 14(10), 468; https://doi.org/10.3390/bios14100468 - 30 Sep 2024
Viewed by 362
Abstract
The evaluation of the upkeep and freshness of aquatic products within the cold chain is crucial due to their perishable nature, which can significantly impact both quality and safety. Conventional methods for assessing freshness in the cold chain have inherent limitations regarding specificity [...] Read more.
The evaluation of the upkeep and freshness of aquatic products within the cold chain is crucial due to their perishable nature, which can significantly impact both quality and safety. Conventional methods for assessing freshness in the cold chain have inherent limitations regarding specificity and accuracy, often requiring substantial time and effort. Recently, advanced sensor technologies have been developed for freshness assessment, enabling real-time and non-invasive monitoring via the detection of volatile organic compounds, biochemical markers, and physical properties. The integration of sensor technologies into cold chain logistics enhances the ability to maintain the quality and safety of aquatic products. This review examines the advancements made in multifunctional sensor devices for the freshness assessment of aquatic products in cold chain logistics, as well as the application of pattern recognition algorithms for identification and classification. It begins by outlining the categories of freshness criteria, followed by an exploration of the development of four key sensor devices: electronic noses, electronic tongues, biosensors, and flexible sensors. Furthermore, the review discusses the implementation of advanced pattern recognition algorithms in sensor devices for freshness detection and evaluation. It highlights the current status and future potential of sensor technologies for aquatic products within the cold chain, while also addressing the significant challenges that remain to be overcome. Full article
(This article belongs to the Special Issue Biosensing Strategies for Food Safety Applications)
Show Figures

Figure 1

13 pages, 3235 KiB  
Article
The Detection of Physiological Changes Using a Triaxial Accelerometer and Temperature Sensor-Equipped Bolus-Type Biosensor in Calves
by Leegon Hong, Younghye Ro, Atsushi Kimura, Woojae Choi and Danil Kim
Animals 2024, 14(19), 2815; https://doi.org/10.3390/ani14192815 - 29 Sep 2024
Viewed by 254
Abstract
In this study, a newly developed small wireless bolus biosensor, equipped with a triaxial accelerometer and temperature sensors, was applied to assess physiological changes in calves. The biosensor was orally implanted in calves, and its retention rate and location in the forestomach were [...] Read more.
In this study, a newly developed small wireless bolus biosensor, equipped with a triaxial accelerometer and temperature sensors, was applied to assess physiological changes in calves. The biosensor was orally implanted in calves, and its retention rate and location in the forestomach were examined. Data transmitted at 10 min intervals were analyzed to determine the characteristics of the calves at 10 and 100 days of age. Additionally, the daily averages of the vector magnitude (DV), changes in V over time (DV1), and reticular temperature (DRT) were analyzed during the experimental period. The biosensor was orally administered to twelve calves (six beef and six dairy) within 22 days of birth. Except for two regurgitated devices, the sensors transmitted data normally in a wireless manner for 15 weeks, recording physiological changes in the calves. The location of the biosensors was confirmed to be the reticulum. The analysis revealed that the V and V1 values were influenced by the physical characteristics of the biosensor’s location. During weaning, DV and DV1 values first increased and then decreased compared to pre-weaning, while the DRT increased post-weaning and remained elevated. These findings suggest that these types of biosensors can be used for monitoring calf health; however, further research is needed to determine their ability to detect pathological states. Full article
(This article belongs to the Section Cattle)
Show Figures

Figure 1

16 pages, 1048 KiB  
Review
Analytical Insights into Methods for Measuring Ischemia-Modified Albumin
by Stefano Zoroddu, Angelo Zinellu, Ciriaco Carru and Salvatore Sotgia
Molecules 2024, 29(19), 4636; https://doi.org/10.3390/molecules29194636 - 29 Sep 2024
Viewed by 313
Abstract
Ischemia-modified albumin (IMA) has emerged as a pivotal biomarker for the early detection of ischemic conditions, particularly myocardial ischemia, where timely diagnosis is crucial for effective intervention. This review provides an overview of the analytical methods for assessment of IMA, including Albumin Cobalt [...] Read more.
Ischemia-modified albumin (IMA) has emerged as a pivotal biomarker for the early detection of ischemic conditions, particularly myocardial ischemia, where timely diagnosis is crucial for effective intervention. This review provides an overview of the analytical methods for assessment of IMA, including Albumin Cobalt Binding (ACB), Albumin Copper Binding (ACuB), Enzyme-Linked Immunosorbent Assay (ELISA), new techniques such as liquid crystal biosensors (LCB), quantum dot coupled X-ray fluorescence spectroscopy (Q-XRF), mass spectrometry (MS), and electron paramagnetic resonance (EPR) spectroscopy. Each method was thoroughly examined for its analytical performance in terms of sensitivity, specificity, and feasibility. The ACB assay is the most readily implementable method in clinical laboratories for its cost-effectiveness and operational simplicity. On the other hand, the ACuB assay exhibits enhanced sensitivity and specificity, driven by the superior binding affinity of copper to IMA. Furthermore, nanoparticle-enhanced immunoassays and liquid crystal biosensors, while more resource-intensive, significantly improve the analytical sensitivity and specificity of IMA detection, enabling earlier and more accurate identification of ischemic events. Additionally, different biological matrices, such as serum, saliva, and urine, were reviewed to identify the most suitable for accurate measurements in clinical application. Although serum was considered the gold standard, non-invasive matrices such as saliva and urine are becoming increasingly feasible due to advances in technology. This review underscores the role of IMA in clinical diagnostics and suggests how advanced analytical techniques have the potential to significantly enhance patient outcomes in ischemic disease management. Full article
(This article belongs to the Special Issue Review Papers in Analytical Chemistry)
Show Figures

Figure 1

25 pages, 2570 KiB  
Review
Application of Active Packaging Films for Extending the Shelf Life of Red Meats: A Review
by Cielo Estefanía Figueroa-Enríquez, Francisco Rodríguez-Félix, Saúl Ruiz-Cruz, Daniela Denisse Castro-Enriquez, Humberto Gonzalez-Rios, José Ángel Perez-Alvarez, José Agustín Tapia-Hernández, Tomás Jesús Madera-Santana, Eneida Azaret Montaño-Grijalva and Itzel Yanira López-Peña
Processes 2024, 12(10), 2115; https://doi.org/10.3390/pr12102115 - 28 Sep 2024
Viewed by 427
Abstract
Meat is known for its high perishability and short shelf life if not properly packaged or stored. Packaging materials play a crucial role in preserving food quality, and there is a growing demand from consumers, industry professionals, and researchers for natural packaging materials [...] Read more.
Meat is known for its high perishability and short shelf life if not properly packaged or stored. Packaging materials play a crucial role in preserving food quality, and there is a growing demand from consumers, industry professionals, and researchers for natural packaging materials that incorporate health-beneficial extracts. Additionally, there is an increasing emphasis on avoiding non-biodegradable plastics in order to reduce environmental pollution. Currently used polymers in food packaging typically feature properties such as oxygen barriers, moisture resistance, and oxidation inhibition, helping to prevent undesirable aromas, flavors, and colors in food. Packaging not only serves as a container for transportation but also prevents physical damage, maintains quality, and ensures food safety. In the pursuit of more sustainable solutions, various compounds are being explored for food packaging, including those derived from proteins, lipids, waxes, and polysaccharides. These materials can be combined with bioactive compounds, such as natural plant extracts, which provide antioxidant, antimicrobial, anti-inflammatory, and anticancer benefits. Different techniques, such as electrohydrodynamic processes and casting methods, are employed in the preparation of these packaging materials. This review highlights the applications and properties of polymers used in meat packaging and promotes the use of biodegradable materials as a viable solution to reduce environmental pollution. Full article
Show Figures

Figure 1

24 pages, 3966 KiB  
Review
Complementary Metal–Oxide–Semiconductor-Based Magnetic and Optical Sensors for Life Science Applications
by Tayebeh Azadmousavi and Ebrahim Ghafar-Zadeh
Sensors 2024, 24(19), 6264; https://doi.org/10.3390/s24196264 - 27 Sep 2024
Viewed by 553
Abstract
Optical and magnetic sensing methods are integral to both research and clinical applications in biological laboratories. The ongoing miniaturization of these sensors has paved the way for the development of point-of-care (PoC) diagnostics and handheld sensing devices, which are crucial for timely and [...] Read more.
Optical and magnetic sensing methods are integral to both research and clinical applications in biological laboratories. The ongoing miniaturization of these sensors has paved the way for the development of point-of-care (PoC) diagnostics and handheld sensing devices, which are crucial for timely and efficient healthcare delivery. Among the various competing sensing and circuit technologies, CMOS (complementary metal–oxide–semiconductor) stands out due to its distinct cost-effectiveness, scalability, and high precision. By leveraging the inherent advantages of CMOS technology, recent developments in optical and magnetic biosensors have significantly advanced their application in life sciences, offering improved sensitivity, integration capabilities, and reduced power consumption. This paper provides a comprehensive review of recent advancements, focusing on innovations in CMOS-based optical and magnetic sensors and their transformative impact on biomedical research and diagnostics. Full article
Show Figures

Figure 1

Back to TopTop