Etoposide, a highly active and widely used antineoplastic agent, is O-demethylated to its active catechol metabolite. A high-performance liquid chromatographic assay method for the simultaneous quantitation of etoposide and etoposide catechol in human plasma was established. Etoposide and etoposide catechol were extracted from plasma using chloroform and methanol followed by phase separation, evaporation of the organic phase, and reconstitution of the residue. Chromatography was accomplished using a reversed-phase phenyl analytical column (390 mm x 3.9 mm I.D.) with a mobile phase of 76.6% 25 mM citric acid-50 mM sodium phosphate (pH 2.4)-23.4% acetonitrile pumped isocratically at 1 ml/min with electrochemical detection. The limit of detection for etoposide was 1.2 nM and for etoposide catechol was 0.2 nM. The precision (CV) for etoposide ranged from 0.7 to 3% and for the catechol metabolite from 1 to 6%; accuracy of predicted values ranged from 97 to 106% and 94 to 103%, respectively. The assay was linear from 0.1 to 10 microM for etoposide and from 0.005 to 0.5 microM for etoposide catechol in plasma. Recovery of etoposide and etoposide catechol ranged from 93 to 95% and 90 to 98%, respectively. Stability of etoposide and etoposide catechol in human plasma containing ascorbic acid stored at -70 degrees C for one year was demonstrated. This assay procedure is suitable for evaluation of etoposide and etoposide catechol pharmacokinetics in plasma following etoposide administration.