Radiological thickness measurement using a liquid ionization chamber electronic portal imaging device

Phys Med Biol. 1999 Jun;44(6):N89-97. doi: 10.1088/0031-9155/44/6/403.

Abstract

We present a method of calibrating the Portal Vision electronic portal imaging device to obtain radiological thickness maps for compensator design. In this method, coefficients are derived to describe the relationship between intensity and thickness for a set of water-equivalent blocks. The effects of four parameters were studied: (a) The dose response of the system was measured and found to be describable by a square-root function. (b) The calibration data and images were taken with a wedge in situ. The effects of using different wedges and different wedge orientations were investigated. The intrinsic accuracy of the accelerator/imager system was found to be 1.9 mm, for both 15 degrees and 30 degrees wedges. Changing the wedge orientation between calibration and imaging and rotating the calibration coefficients accordingly led to an error of 3.5 mm. (c) The variation in detector response with gantry angle was measured and corrected. The residual error in this process was 2.4 mm. (d) The use of a model to correct the effects of imaging with different field sizes was investigated and found to yield a residual error of 2.9 mm. The overall error in image calibrations was approximately 4 mm or 2% in dose. This is considered to be sufficiently small for the intended use of designing compensators for tangential breast irradiation.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Diagnostic Imaging / instrumentation*
  • Diagnostic Imaging / methods*
  • Dose-Response Relationship, Radiation
  • Humans
  • Mammography / instrumentation
  • Models, Theoretical
  • Phantoms, Imaging
  • Radiotherapy Planning, Computer-Assisted