Wire-snare technique with distal flow control for coil occlusion of a modified Blalock-Taussig shunt

Catheter Cardiovasc Interv. 2000 Jan;49(1):51-4. doi: 10.1002/(sici)1522-726x(200001)49:1<51::aid-ccd10>3.0.co;2-u.

Abstract

Coil occlusion of Blalock-Taussig shunts has been associated with a high rate of device embolization. We describe a technique consisting of transvenous snaring and exteriorization of a guidewire advanced through a modified left Blalock-Taussig shunt, allowing distal shunt flow control and successful coil occlusion of the shunt. Cathet. Cardiovasc. Intervent. 49:51-54, 2000.

Publication types

  • Case Reports

MeSH terms

  • Anastomosis, Surgical
  • Cardiac Catheterization
  • Child
  • Embolization, Therapeutic / instrumentation
  • Embolization, Therapeutic / methods*
  • Female
  • Humans
  • Pulmonary Artery / diagnostic imaging
  • Pulmonary Artery / surgery*
  • Radiography, Interventional
  • Subclavian Artery / diagnostic imaging
  • Subclavian Artery / surgery*
  • Tetralogy of Fallot / diagnostic imaging
  • Tetralogy of Fallot / surgery*