Peripheral flow response to transient arterial forearm occlusion does not reflect myocardial perfusion reserve

Circulation. 2001 Feb 27;103(8):1109-14. doi: 10.1161/01.cir.103.8.1109.

Abstract

Background: Ultrasonographic evaluation of systemic arterial function is widely available, and a close relation of endothelial function in the coronary and brachial arteries has been documented. It is unknown, however, whether a similar correlation exists for their 2 microcirculatory territories and thus whether assessment of the systemic microcirculation can be used similarly as a surrogate marker of myocardial perfusion.

Methods and results: Twenty-three patients with documented coronary artery disease (CAD; 66+/-9 years old, 18 men), 16 patients with syndrome X (SX; 56+/-5 years old, 13 women), and 45 healthy control subjects (C; 34+/-9 years old, 22 men) were studied. Myocardial perfusion was measured at rest and after dipyridamole (0.56 mg. kg(-1). min(-1) over 4 minutes) by PET, and brachial artery blood flow was measured at rest and after transient forearm ischemia by standard Doppler ultrasound techniques. Dipyridamole increased myocardial perfusion in all groups (mL. g(-1). min(-1): CAD, 0.89+/-0.27 versus 1.62+/-0.67, P:<0.001; SX, 0.82+/-0.16 versus 1.67+/-0.49, P:<0.001; and C, 0.82+/-0.15 versus 2.32+/-0.64, P:<0.001). Postocclusion forearm flow increased similarly in all groups (CAD, 52+/-18 versus 174+/-77 mL/min, P:<0.001; SX, 49+/-29 versus 202+/-82 mL/min, P:<0.001; and C, 61+/-34 versus 229+/-108 mL/min, P:<0.001). No significant correlations were found between peripheral and myocardial microcirculatory beds for either resting flow, hyperemic flow, or flow reserve in any of the groups (r(2)<0.1, P:=NS).

Conclusions: The peripheral perfusion responses to transient forearm ischemia do not correlate with dipyridamole-induced myocardial hyperemia. The lack of correlation indicates different mechanisms of microvascular activation or regulation and confirms that extrapolations between findings in the 2 vascular beds are not suitable.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Arterial Occlusive Diseases / diagnostic imaging
  • Arterial Occlusive Diseases / physiopathology*
  • Blood Pressure
  • Brachial Artery / physiology
  • Female
  • Forearm
  • Humans
  • Male
  • Microcirculation
  • Middle Aged
  • Myocardial Ischemia / physiopathology
  • Perfusion
  • Statistics as Topic
  • Ultrasonography
  • Vasodilation