Accuracy and effectiveness of laparoscopic vs open hepatic radiofrequency ablation

Surg Endosc. 2001 Feb;15(2):135-40. doi: 10.1007/s004640080066.

Abstract

Background: The purpose of this study was to compare the accuracy (in terms of ultrasound-guided probe placement) and the effectiveness (in terms of pathologic tumor-free margin) of laparoscopic vs open radiofrequency (RF) ablation.

Methods: Using a previously validated tissue-mimic model, 1-cm simulated hepatic tumors were ablated in 10 pigs randomized to open or laparoscopic techniques. Energy was applied until tissue temperature reached 100 degrees C (warm-up) and thereafter for 8 min. A pathologist blinded to technique examined all specimens immediately after treatment. Analysis was by Fisher's exact test and the Mann-Whitney U test; p < 0.05 was considered significant.

Results: Off-center distance (3.5 +/- 1.6 vs 4.2 +/- 1.4 mm), size (24.7 +/- 3.1 vs 25.6 +/- 3.8 mm), symmetry (40% vs 73%), margin positivity (33% vs 9%), and margin distance (1.1 +/- 1.2 vs 2.2 +/- 1.6 mm) were not significantly different between laparoscopic (n = 15) and open (n = 11) ablations, respectively. The proportion of round/ovoid lesions (20% vs 64%) was lower (p = 0.043), and warm-up time (20.2 +/- 14.0 vs 10.7 +/- 7.5) was longer (p = 0.049) for the laparoscopic than for the open groups, respectively.

Conclusion: Accurate probe placement can be achieved using laparoscopic and open RF ablation techniques. The physiologic effects of laparoscopy may alter ablation shape and warm-up time. Additional studies are needed to establish effective ways of achieving complete tumor destruction.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Catheter Ablation / methods*
  • Disease Models, Animal
  • Laparoscopy / methods*
  • Liver Neoplasms / surgery*
  • Probability
  • Random Allocation
  • Sensitivity and Specificity
  • Statistics, Nonparametric
  • Swine