Intraoperative proximal endoleaks during AAA stent-graft repair: evaluation of risk factors and treatment with Palmaz stents

J Endovasc Ther. 2001 Jun;8(3):268-73. doi: 10.1177/152660280100800306.

Abstract

Purpose: To study factors that might contribute to intraoperative proximal type I endoleak and to evaluate the placement of giant Palmaz stents as a therapeutic option.

Methods: Thirty-three patients (30 men; median age 72 years, range 50-85) with abdominal aortic aneurysms underwent implantation of fully supported Gianturco Z-stent-based endografts (12 custom-made aortomonoiliac and 21 bifurcated Zenith devices). Ten (30%) patients were treated for intraoperative proximal endoleaks. Stent-graft oversizing and neck angulation, length, and shape were compared between patients with and without leaks.

Results: In 9 cases, the endoleaks were successfully treated with intraoperative placement of Palmaz stents without complications. In 1 patient, a leak that was resolved intraoperatively with balloon dilation reappeared 1 month later; a Palmaz stent was deployed successfully. Stent-graft oversizing did not differ significantly between patients who developed proximal endoleaks and those who did not (median 4.0 mm in both groups, p = 0.47). Median neck length was 21.0 mm in patients with endoleak and 28.0 mm in those without (p > 0.99). Median neck angulation was 30 degrees in both groups (p = 0.33), and the presence of a conical aneurysm neck was not significantly different (2/10 versus 6/23, p > 0.99). All aneurysms remained excluded at a median follow-up of 13 months (range 6-24).

Conclusions: Stent-graft oversizing and neck morphology (length, angulation, and conical shape) do not seem to correlate with the incidence of proximal type I endoleaks. Palmaz stent placement appears to be a feasible and safe treatment option for this complication.

Publication types

  • Comparative Study
  • Evaluation Study

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Aneurysm, Abdominal / complications*
  • Aortic Aneurysm, Abdominal / therapy*
  • Catheterization / instrumentation
  • Female
  • Follow-Up Studies
  • Humans
  • Intraoperative Complications / etiology*
  • Male
  • Middle Aged
  • Risk Factors
  • Stents*
  • Treatment Outcome
  • Vascular Surgical Procedures / instrumentation