Charcoal and sodium nitrate, the active ingredients in pesticide gas cartridges, are quantified via carbon analysis and ion chromatography, respectively. Linearity was excellent (R(2) > 0.995) over a range consisting of 50-150% of the target concentration for both ingredients. The coefficient of variation for the replicate analyses of gas cartridges over multiple days was <4% for both analytes. Using the results from the analysis of two batches of gas cartridges, theoretical populations were modeled and used to determine practical sampling strategies to support a quality control program for a gas cartridge manufacturing operation. This modeling indicates that the analysis of three cartridges from each of five different lots would produce mean values for both active ingredients that are within 5% of the true mean >99% of the time.