CD34(+) cell collection efficiency does not correlate with the pre-leukapheresis hematocrit

Bone Marrow Transplant. 2001 Sep;28(6):597-601. doi: 10.1038/sj.bmt.1703197.

Abstract

One hundred and seventy-seven large-volume leukapheresis procedures performed on 91 patients over a 15 month period were reviewed to see if the pre-apheresis hematocrit (Hct) affected the CD34(+) cell collection efficiency (CE) of the Fenwal CS 3000 Plus cell separator. The Hct was 0.174-0.461 (median 0.317), and the peripheral blood CD34(+) cell count 2-2487 per microl (median 21). The total CD34(+) cell quantity collected was 3.0-2677.2 x 10(6) (median 113.0). Based on the number of CD34(+)cells contained in the blood volume processed (23.3-37303.2 x 10(6); median 318.0), the CE was 1.7-87.5% (median 30.3). No correlation was found between the Hct and CE (r(2) = 0.0034; P = 0.44) or the total CD34(+) cell quantity collected (r2 = 0.0040; P = 0.40). CEs for Hct <0.25 (median CE 36%), Hct 0.25-0.299 (median CE 30%) and Hct 0.30 (median CE 30%) were comparable. As expected, highly significant correlations were seen between the CD34(+) cell quantities collected and quantities processed (r2 = 0.59; P < 10(-6)) as well as the peripheral blood CD34(+) cell counts (r2= 0.60; P < 10(-6)). We conclude that the minimum acceptable Hct or hemoglobin level for leukapheresis should be dictated by clinical circumstances because it does not affect stem cell collection.

MeSH terms

  • Antigens, CD34 / blood*
  • Hematocrit*
  • Hematologic Diseases / therapy
  • Hemoglobins / metabolism
  • Humans
  • Leukapheresis / standards*
  • Lymphocyte Count
  • Regression Analysis
  • Retrospective Studies

Substances

  • Antigens, CD34
  • Hemoglobins