Direct identification and susceptibility testing of enteric bacilli from positive blood cultures using VITEK (GNI+/GNS-GA)

Clin Microbiol Infect. 2002 Jan;8(1):38-44. doi: 10.1046/j.1469-0691.2002.00372.x.

Abstract

Objective: To study the possibility of reporting results of identification and susceptibility testing of Gram-negative bacilli the same day as bacteremia is detected by using direct inoculation from positive blood cultures (Bactec 9240) into VITEK GNI+ and GNS-GA cards.

Methods: All blood cultures with Gram-negative enteric bacillus-like morphology on microscopy found to be positive on workdays between 15 June 1999 and 29 February 2000 were included. Identification and susceptibility testing were done by three methods: the direct method using a suspension made by differential centrifugation of positive blood culture broth for inoculation of the VITEK cards; the standard method using an inoculum made from an overnight culture on a solid media; and the routine method (reference method) using conventional testing.

Results: Of 169 isolates, the direct method resulted in 75% correct identifications, 9% misidentifications and 17% non-identifications. All misidentified isolates were Escherichia coli, of which 80% were reported as Salmonella arizonae. Five biochemical tests yielded most of the aberrant results; correcting the citrate and malonate reactions in most cases led to correct identification by the VITEK database. Despite a negative H2S reaction, 11 E. coli isolates were reported as S. arizonae. Two-thirds (69%) of identifications were reported within 6 h, and 95% of these were correct. The direct susceptibility testing method was assessable for 140 isolates. Correct results were found in 99% of isolate-antimicrobial combinations, and 85% were reported within 6 h.

Conclusion: The direct VITEK method could correctly report identifications and susceptibility patterns within 6 h, making same-day reporting possible for almost two-thirds (63%) of bacteremic episodes with Gram-negative bacilli. These results could probably be improved by modification of the identification algorithms of the VITEK software.

Publication types

  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Bacteremia / diagnosis
  • Bacteriological Techniques*
  • Enterobacteriaceae / drug effects
  • Enterobacteriaceae / isolation & purification*
  • Enterobacteriaceae Infections / diagnosis*
  • Enterobacteriaceae Infections / microbiology
  • Escherichia coli / drug effects
  • Escherichia coli / isolation & purification
  • Humans
  • Microbial Sensitivity Tests / methods*
  • Salmonella / isolation & purification
  • Salmonella arizonae / drug effects
  • Salmonella arizonae / isolation & purification
  • Software