Optimization of solid-phase clean-up prior to liquid chromatographic analysis of ochratoxin A in roasted coffee

J Chromatogr A. 2002 Jun 14;959(1-2):327-30. doi: 10.1016/s0021-9673(02)00408-9.

Abstract

An extraction and clean-up method for ochratoxin A (OA) in roasted coffee has been developed and the HPLC method optimized. An interfering compound with a similar retention time as OA was adsorbed by the aminopropyl (NH2) material at < or = 5% NaHCO3. Residual OA on the column was recovered by washing with the extraction solution followed with methanol. Fractions were mixed together for further clean-up with Ochratest immunoaffinity columns (IACs). Analysis by HPLC resulted in a well resolved OA peak and reduction in matrix interferences. Recoveries ranged from 72 to 84% and the detection limit was 1 ng/g.

MeSH terms

  • Chromatography, High Pressure Liquid / methods*
  • Coffee / chemistry*
  • Mycotoxins / analysis*
  • Ochratoxins / analysis*
  • Spectrometry, Fluorescence

Substances

  • Coffee
  • Mycotoxins
  • Ochratoxins
  • ochratoxin A