Input-size dependence of the baroreflex neural arc transfer characteristics

Am J Physiol Heart Circ Physiol. 2003 Jan;284(1):H404-15. doi: 10.1152/ajpheart.00319.2002. Epub 2002 Sep 26.

Abstract

Static characteristics of the baroreflex neural arc from pressure input to sympathetic nerve activity (SNA) show sigmoidal nonlinearity, whereas its dynamic characteristics approximate a derivative filter where the magnitude of SNA response becomes greater as the input frequency increases. To reconcile the static nonlinear and dynamic linear components, we examined the effects of input amplitude on the apparent linear transfer function of the neural arc. In nine anesthetized rabbits, we perturbed isolated carotid sinus pressure by using binary white noise while varying the input amplitude among 5, 10, 20, and 40 mmHg. With increasing input amplitude, the transfer gain at 0.01 Hz decreased from 1.21 +/- 0.27 to 0.49 +/- 0.28 arbitrary units/mmHg (P < 0.01). Moreover, the slope of the transfer gain between 0.03 and 0.3 Hz decreased from 14.3 +/- 3.7 to 6.5 +/- 2.5 dB/decade (P < 0.01). We conclude that the model consisting of a sigmoidal component following rather than preceding a derivative component explains the observed results and thus can be used as a first approximation of the overall neural arc transfer characteristics.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Acoustic Stimulation / methods
  • Animals
  • Baroreflex / physiology*
  • Blood Pressure / physiology
  • Carotid Sinus / physiology
  • Efferent Pathways / physiology
  • Fourier Analysis
  • In Vitro Techniques
  • Linear Models
  • Models, Cardiovascular
  • Noise
  • Rabbits
  • Sympathetic Nervous System / physiology*