Volume dependence of airway and tissue impedances in mice

J Appl Physiol (1985). 2003 Apr;94(4):1460-6. doi: 10.1152/japplphysiol.00596.2002. Epub 2002 Aug 30.

Abstract

We measured respiratory input impedance (1-25 Hz) in mice and obtained parameters for airway and tissue mechanics by model fitting. Lung volume was varied by inflating to airway opening pressure (Pao) between 0 and 20 cm H2O. The expected pattern of changes in respiratory mechanics with increasing lung volume was seen: a progressive fall in airway resistance and increases in the coefficients of tissue damping and elastance. A surprising pattern was seen in hysteresivity (eta), with a plateau at low lung volumes (Pao < 10 cm H2O), a sharp fall occurring between 10 and 15 cm H2O, and eta approaching a second (lower) plateau at higher lung volumes. Studies designed to elucidate the mechanism(s) behind this behavior revealed that this was not due to chest wall properties, differences in volume history at low lung volume, time dependence of volume recruitment, or surface-acting forces. Our data are consistent with the notion that at low lung volumes the mechanics of the tissue matrix determine eta, whereas at high lung volumes the properties of individual fibers (collagen) become more important.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Airway Resistance*
  • Animals
  • Female
  • Functional Residual Capacity
  • Lung / physiology*
  • Lung Volume Measurements
  • Mice
  • Mice, Inbred BALB C
  • Respiratory Mechanics
  • Thorax / physiology
  • Time Factors
  • Total Lung Capacity