LC-MS/MS determination of a farnesyl transferase inhibitor in human plasma and urine

J Pharm Biomed Anal. 2002 Nov 7;30(4):1157-71. doi: 10.1016/s0731-7085(02)00451-x.

Abstract

To support clinical pharmacokinetic studies in cancer patients, sensitive and specific methods for measuring 4-[1-(4-cyanobenzyl)-5-imidazolylmethyl]-1-(3-chlorophenyl) piperazinone (I), a farnesyl transferase inhibitor (FTI), in human plasma and urine were developed and validated. The methods are based on high-performance liquid chromatography (HPLC) with atmospheric pressure chemical ionization (APCI) and tandem mass spectrometric (MS/MS) detection in the positive ion mode using a heated nebulizer interface. Drug and internal standard were isolated from plasma or basified urine using automated solid-phase extraction on cyano cartridges. The organic extracts were dried, reconstituted in aqueous acetonitrile and injected into the system. Chromatographic separation of I and internal standard (IS) was achieved using a BDS Hypersil C8 analytical column, with a mobile phase consisting of acetonitrile:methanol:water (50:4:46) and trifluoroacetic acid (0.05%) at a flow rate of 0.6 ml/min. MS/MS detection was performed on a PE-Sciex API 300 tandem mass spectrometer operated in selected reaction monitoring mode. The parent-->product ions monitored were m/z 406-->195 for analyte I and m/z 448-->195 for the internal standard. Unusual in this method is that quantitation is accomplished using a secondary product ion, m/z 195, of drug I and IS. The assays were validated over the concentration range of 0.5-1000 ng/ml (1.2 nM to 2.5 microM, respectively) in plasma, and 2.5-500 ng/ml (6.2 nM to 1.23 microM) in urine. Accuracy was within +/-10% of nominal concentration at all levels in urine, and all but the lowest standard in plasma (+/-14% at 0.5 ng/ml). Intraday precision (expressed as coefficients of variation, CVs) for standard replicates and interday precision for quality control (QC) samples were less than 8% at all concentrations in both matrices. Detailed descriptions of the extraction procedure and analytical methodology used in the assay of I in plasma and urine are presented. This procedure may have utility in the quantitation of other imidazole-based FTIs with cyanobenzyl substructures.

MeSH terms

  • Alkyl and Aryl Transferases / antagonists & inhibitors*
  • Enzyme Inhibitors / blood*
  • Enzyme Inhibitors / chemistry
  • Enzyme Inhibitors / urine*
  • Farnesyltranstransferase
  • Humans
  • Mass Spectrometry / methods

Substances

  • Enzyme Inhibitors
  • Alkyl and Aryl Transferases
  • Farnesyltranstransferase