The influence of working cast residual moisture and temperature on the fit of vacuum-forming athletic mouth guards

J Prosthet Dent. 2003 Jan;89(1):23-7. doi: 10.1067/mpr.2003.62.

Abstract

Statement of problem: The comfort and effectiveness of athletic mouth guards are believed to depend on their degree of fit to oral tissues. Vacuum-forming machines are simpler and less expensive than pressure-forming machines. However, it is thought that vacuum-formed mouth guards often do not exhibit adequate adaptation.

Purpose: The purpose of this study was to evaluate the effects of cast residual moisture and temperature on the fit of athletic mouth guards made with a vacuum-forming machine.

Material and methods: A metal master model simulating the cross section of the maxillary molar region was used to form 20 working plaster casts. The casts represented 4 (5 specimens each) conditions before the forming of the mouth guard specimens: storing in a wet environment at room temperature and storing in a dry environment at room temperature, 5 degrees C, and 40 degrees C. Mouth guard specimens were fabricated with ethylene vinyl acetate sheets (3.8-mm thick) with the use of a vacuum-forming machine. Test casts were created by pouring hand-mixed type III dental stone into each of the mouth guard specimens. The differences in the sagittal cross-sectional heights at the line angle area of the test casts and the working casts were compared. This was achieved by superimposing their 3-dimensional images scanned by a laser scanner. The air permeability was also measured for the hand-mixed stone casts under wet and dry conditions, the vacuum-mixed stone cast, and the high-strength stone specimen. This was achieved by measuring the volume of transmitted air passing through the specimen in the testing tube. One-way analysis of variance with the Scheffé post hoc test (P <.05) was applied to determine the conditions of the working cast required to achieve the best fit.

Results: With regard to the fit of the mouth guard specimens to the working cast, those with dry and heated working casts showed a significantly better fit than those with wet working casts (P<.05). A significantly larger volume of transmitted air was found in the dry stone specimen (P<.05) followed by the dry high-strength stone cast and then the wet stone cast.

Conclusion: Within the limitations of this study, residual moisture in the working cast was the most critical factor in determining the fit of the mouth guard made by vacuum-forming machines. The best fit was achieved when the working cast was thoroughly dried and its surface temperature was elevated.

Publication types

  • Comparative Study

MeSH terms

  • Air
  • Analysis of Variance
  • Calcium Sulfate / chemistry
  • Cold Temperature
  • Dental Casting Investment / chemistry*
  • Equipment Design
  • Hot Temperature
  • Humans
  • Image Processing, Computer-Assisted
  • Lasers
  • Models, Dental*
  • Mouth Protectors*
  • Permeability
  • Polyvinyls / chemistry*
  • Statistics as Topic
  • Surface Properties
  • Vacuum
  • Water / chemistry*

Substances

  • Dental Casting Investment
  • Polyvinyls
  • Water
  • ethylenevinylacetate copolymer
  • Calcium Sulfate